Available languages

Button
Buttons
REGENERATE (R)
CHANGE (C)
SELECT (S)
The CHANGE (C), SELECT (S), DISPLAY (P), and SCROLL BACK ( ) buttons are used when
changing Customer Settings and Service Settings.
The REGENERATE (R) button can be used in three ways.
1. The REGENERATE (R) button can be used to put the appliance into an immediate
regeneration.
a. Press and hold the REGENERATE (R) button for about five seconds until the display changes
to "Going to 1".
b. The appliance is in regeneration mode and will display the status of each cycle. After all
regeneration cycles are complete, the display will return to normal operating mode.
2. The REGENERATE (R) button can be used to toggle through all of the regeneration cycles to
speed up the cycles.
a. Speeding up the cycle is used only when starting up or diagnosing the appliance.
b. To quickly advance through the regeneration cycles, press and hold the REGENERATE (R)
button for five seconds to start a regeneration.
c. Wait for the cycle to begin. The controller will indicate "Going to", then the cycle position
will display (for example, Backwash 1).
d. Each cycle can be advanced by pressing the REGENERATE (R) button.
e. Always wait until the cycle position displays before advancing to the next cycle position.
3. Press and release the REGENERATE (R) button in Normal operating mode to schedule a
regeneration tonight or toggle it off.
The REGENERATE button can also be used to restore capacity if you run out of salt.
Out of Salt
Should your appliance run out of salt, you might not have soft water available.
1. Open the salt port lid and add salt.
2. Wait two hours, then press and hold the REGENERATE (R) button for 2 to 5 seconds.
3. Regeneration is complete after approximately 12 to 18 minutes. After regeneration the
appliance is returned to Service mode.
The CHANGE (C) button is used with the SELECT (S) button to set the value of certain
parameters.
1. When you press the CHANGE (C) button, the value under the cursor changes to the next
available value, typically increasing by one until all values have been displayed and the
process begins again.
The SELECT (S) button is used to move the cursor when setting parameters.
1. Press and release the SELECT (S) button to move the cursor one digit to the right of the
parameter to be changed.
2. When the cursor is at the extreme right position, press the SELECT (S) button again to reset
the cursor to the extreme left position.
Function