A.O. Smith TRIASOFT MINI User Manual page 21

Cabinet water softener system
Table of Contents

Advertisement

Available languages

Available languages

7
Check for leaks
7.1 Close all faucets.
7.2 Check all lines and connections for leaks. If leaks are found:
7.2.1 Turn off the main water supply.
7.2.2 Open a cold water faucet to depressurize the lines.
7.2.3 Close the faucet to eliminate any siphoning action.
7.2.4 Repair all leaks.
7.2.5 Turn on the water supply.
7.2.6 Place the appliance in the Service position to slowly fill the media
tank (Diagram 13).
7.2.7 Open a cold water faucet to purge air out of the media tank.
7.2.8 Close the faucet and recheck for leaks.
Water Softener Model 410 Normal Operation Diagram
Mains
Incoming Mains
Stopcock
Water Supply
Overflow Line
and Drain Line
2" (50mm) Air Gap
Hard Water To
Outside Taps &
Drinking Water
Bypass
Valve in
Closed Position
Inlet
Valve in
Open
Position
Diagram 13: Service Position
8
Connect the Controller
8.1 Make sure the controller is properly attached to the drive end cap
(Diagram 14).
8.2 Make sure the Turbine Sensor wire and the motor wire are plugged
into the controller.
8.3 Connect the transformer power cord to the controller (Diagram 15).
Do not plug the transformer into the wall yet.
8.4 Make sure the transformer cord is fed through the same area as the
drain and water lines.
8.5 Replace the valve cover.
Cold Soft
Water To
Property
Outlet
Valve in
Open
Position
Diagram 14: Controller Tab Lock Detail
Diagram 15:Connect Transformer Power Cord