Mesuring
Item
instrument
NTSC
Remote control
CONTRAST
unit
Signal generator
Item No.
Setting value
F46
090
165
F47
165
F48
Adjust this portion to white
Test point
Adjustment part
[2. YC SEP]
YCM132: (NO DISPLAY)
(CONTRAST)
[1. PICTURE/SOUND]
S13: RDRV (R DRIVE)
S15: GDRV (G DRIVE)
S17: BDRV (B DRIVE)
S19: CUTR (R CUTOFF)
S21: CUTG (G CUTOFF)
S23: CUTB (B CUTOFF)
F44: (NO DISPLAY)
(Picture control)
F45: (NO DISPLAY)
(Picture control mode sw)
F46: OUT LV.
(Output level upon
detection)
F47: LMT BTM
(Minimum value upon
detection)
F48: LMT TOP
(Maximum value upon
detection)
Adjustment item
Output level upon detection
Minimum value upon detection
Maximum value upon detection
Fig.6
Description
(1) Input NTSC composite all-white signal.
(2) Set "VIDEO STATUS" to STANDARD.
(3) Set "ASPECT" to FULL.
(4) Select "COLOR TEMPERATURE" to LOW.
(5) Select "1.PICTURE/SOUND" from the SERVICE
MODE.
(6) Set < S13 > (R DRIVE), < S15 > (G DRIVE) and
< S17 > (B DRIVE) to "255".
(7) Set < S19 > (R CUTOFF), < S21 > (G CUTOFF) and
< S23 > (B CUTOFF) to "128".
(8) Set < F44 > (Picture control) to "001" and < F45 >
(Picture control mode sw) to "000" to set Y ADJUST
MAX MODE.
(9) Set < F46 > (Output level upon detection), < F47 >
(Minimum value upon detection) and < F48 >
(Maximum value upon detection) to values as
shown in the left table.
(10) Press the [MUTING] key to memorize the set
values.
(11) Select "2. YC SEP" from the SERVICE MODE.
(12) Adjust < YCM132 > (CONTRAST) to set the white
portion on the lower half of the screen to white color.
(Fig.6)
(13) Press the [MUTING] key to memorize the set
values.
(14) Select "1.PICTURE/SOUND" from the SERVICE
MODE.
(15) Set < F44 > (Picture control) to "000" to cancel Y
ADJUST MAX MODE.
(16) Press the [MUTING] key to memorize the set
values.