Lenovo Flex System x440 Product Manual
Lenovo Flex System x440 Product Manual

Lenovo Flex System x440 Product Manual

Compute node

Advertisement

Quick Links

Flex System x440 Compute Node (7917)
Product Guide
A building block for the ® PureFlex™ System family, the Flex System™ x440 Compute Node is a four-socket Intel
Xeon processor-based server optimized for high-end virtualization, mainstream database deployments, and
memory-intensive high performance environments. It is price-performance optimized with a wide range of
processors, memory, and I/O options to help you match system capabilities and cost to workloads without
compromise. With a dense design, the Flex System x440 Compute Node can help reduce floor space used, and
lower data center power and cooling costs.
Suggested usage: Database, virtualization, and enterprise applications.
Figure 1 shows the Flex System x440 Compute Node.
Figure 1. The Flex System x440 Compute Node
Did you know?
Flex System is a new category of computing that integrates multiple server architectures, networking, storage, and
system management capability into a single system that is easy to deploy and manage. Flex System has full, built-in
virtualization support of servers, storage, and networking to speed provisioning and increased resiliency. In addition,
it supports open industry standards, such as operating systems, networking and storage fabrics, virtualization, and
system management protocols, to easily fit within existing and future data center environments. Flex System is
scalable and extendable with multi-generation upgrades to protect and maximize IT investments.
Check for Updates
Flex System x440 Compute Node (7917)
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo Flex System x440

  • Page 1 I/O options to help you match system capabilities and cost to workloads without compromise. With a dense design, the Flex System x440 Compute Node can help reduce floor space used, and lower data center power and cooling costs.
  • Page 2: Key Features

    Solid-state drives (SSDs), which offer better reliability than traditional mechanical HDDs for greater uptime. Flex System x440 Compute Node (7917)
  • Page 3 SSDs consume as much as 80% less power than traditional spinning 2.5-inch HDDs. The x440 uses hexagonal ventilation holes, a part of IBM Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient airflow through the system. Flex System x440 Compute Node (7917)
  • Page 4: Locations Of Key Components And Connectors

    Locations of key components and connectors Figure 2 shows the front of the server. Figure 2. Front view of the Flex System x440 Compute Node Flex System x440 Compute Node (7917)
  • Page 5: Standard Specifications

    Figure 3 shows the locations of key components inside the server. Figure 3. Inside view of the Flex System x440 Compute Node Standard specifications The following table lists the standard specifications. Table 1. Standard specifications Flex System x440 Compute Node (7917)
  • Page 6 Four 10 Gb Ethernet ports with two dual-port Embedded 10Gb Virtual Fabric Ethernet interfaces LAN-on-motherboard (LOM) controllers; Emulex BE3 based. Upgradeable to FCoE and iSCSI using the Lenovo Feature on Demand (FoD) license activation. x2x models: None standard; optional 1 Gb or 10 Gb Ethernet adapters. PCI Expansion Four I/O connectors for adapters.
  • Page 7: Standard Models

    Service and Optional service upgrades are available through the ServicePac® feature: Four-hour or 2-hour response support time, 8-hour fix time, 1-year or 2-year warranty extension, remote technical support for Lenovo hardware and selected Lenovo and OEM software. Dimensions Width: 437 mm (17.2 inches), height 51 mm (2.0 inches), depth 493 mm (19.4 inches) Weight Maximum weight: 12.25 kg (27 lbs)
  • Page 8: Chassis Support

    ‡ The x4x models include two Embedded 10Gb Virtual Fabric Ethernet controllers. Connections are routed using a Fabric Connector. The Fabric Connectors preclude the use of an I/O adapter in I/O connectors 1 and 3, except the ServeRAID M5115 controller, which can be installed in slot 1. Chassis support Flex System x440 Compute Node (7917)
  • Page 9: Processor Options

    N+N, N=3 6 power 5 power 4 power 6 power 6 power 5 power 4 power 6 power supplies supplies supplies supplies supplies supplies supplies supplies 95 W 115 W 130 W Processor options Flex System x440 Compute Node (7917)
  • Page 10: Memory Options

    * When two feature codes are specified, the first feature code is for CPU 1 and the second feature code is for CPU Memory options Lenovo DDR3 memory is compatibility tested and tuned for optimal performance and throughput. Lenovo memory specifications are integrated into the light path diagnostic tests for immediate system performance feedback and optimum system uptime.
  • Page 11 * The maximum quantity supported is shown for four processors installed. When two processors are installed, the maximum quantity supported is a half of the quantity that is shown. When one processor is installed, the quantity is one quarter of that shown. The following memory protection technologies are supported: Flex System x440 Compute Node (7917)
  • Page 12: Internal Storage

    16GB (1x16GB, 2Rx4, 1.5V) PC3-12800 CL11 ECC DDR3 48 (12 per 1600MHz LP RDIMM processor) LRDIMMs 90Y3105 A291 32GB (1x32GB, 4Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 48 (12 per 1333MHz LP LRDIMM processor) Internal storage Flex System x440 Compute Node (7917)
  • Page 13 The ServeRAID M5115 hardware kits are as follows: ServeRAID M5100 Series Enablement Kit for Flex System x440 (46C9030) enables support for up to two 2.5-inch HDDs or SSDs in the hot-swap bays in the front of the server. It includes a CacheVault unit, which enables MegaRAID CacheVault flash cache protection.
  • Page 14 This v2 kit provides support for the latest high- performance SSDs. ServeRAID M5100 Series SSD Expansion Kit for Flex System x440 (46C9032) enables support for up to four internal 1.8-inch SSDs. This kit includes two air baffles which can attach two 1.8-inch SSD attachment locations and flex cables for attachment to up to four 1.8-inch SSDs.
  • Page 15 Figure 5. ServeRAID M5115 with Flash and SSD Expansion Kits installed The eight SSDs are installed in the following locations: Four in the front of the system in place of the two 2.5-inch drive bays Flex System x440 Compute Node (7917)
  • Page 16 ServeRAID M5100 Series SSD Caching Enabler for Flex System (MegaRAID CacheCade Pro 2.0) These features are described as follows: RAID 6 Upgrade (90Y4410) Adds support for RAID 6 and RAID 60. This is a Feature on Demand license. Performance Upgrade (90Y4412) Flex System x440 Compute Node (7917)
  • Page 17: Internal Drive Options

    Internal drive options The 2.5-inch drive bays support SAS or SATA HDDs or SATA SSDs. The following table lists the supported 2.5-inch drive options. Table 10. 2.5-inch drive options for internal disk storage Flex System x440 Compute Node (7917)
  • Page 18 90Y8953 A2XE 500GB 7.2K 6Gbps NL SAS 2.5" SFF G2HS HDD 81Y9690 A1P3 1TB 7.2K 6Gbps NL SAS 2.5" SFF HS HDD SAS-SSD Hybrid drive 00AD102 A4G7 600GB 10K 6Gbps SAS 2.5'' G2HS Hybrid Flex System x440 Compute Node (7917)
  • Page 19 S3500 80GB SATA 1.8" MLC Enterprise Value SSD 00AJ045 A4KW S3500 240GB SATA 1.8" MLC Enterprise Value SSD 00AJ050 A4KX S3500 400GB SATA 1.8" MLC Enterprise Value SSD 00AJ455 A58U S3500 800GB SATA 1.8" MLC Enterprise Value SSD Flex System x440 Compute Node (7917)
  • Page 20: Optical Drives

    The x440 has four I/O expansion connectors for attaching I/O adapter cards, as shown in Figure 6. There is a fifth expansion connector (under I/O adapter 4) designed for future expansion options. The I/O expansion connector is a Flex System x440 Compute Node (7917)
  • Page 21 Figure 6 shows the location of the I/O expansion connectors. Figure 6. Location of the I/O adapter slots in the Flex System x440 Compute Node All I/O adapters are the same shape and can be used in any available slot. A compatible switch or pass-through module must be installed in the corresponding I/O bays in the chassis, as indicated in the following table.
  • Page 22 Port 4 (for 4-port cards) Module bay 2 Slot 4 Port 1 Module bay 3 Port 2 Module bay 4 Port 3 (for 4-port cards) Module bay 3 Port 4 (for 4-port cards) Module bay 4 Flex System x440 Compute Node (7917)
  • Page 23: Network Adapters

    Figure 7. Location of the switch bays in the Flex System Enterprise Chassis Figure 8 shows how 2-port adapters are connected to switches installed in the chassis. Figure 8. Logical layout of the interconnects between I/O adapters and I/O modules Network adapters Flex System x440 Compute Node (7917)
  • Page 24: Storage Host Bus Adapters

    Connectors if you plan to install adapters in those I/O slots. To use slots 3 and 4 requires the second processor. For adapter-to-switch compatibility, see the Flex System Interoperability Guide: http://www.redbooks.ibm.com/fsig For more information, see the list of Product Guides in the Adapter cards category: http://www.redbooks.ibm.com/portals/puresystems?Open&page=pg&cat=adapters Storage host bus adapters Flex System x440 Compute Node (7917)
  • Page 25: Power Supplies

    Connectors if you plan to install adapters in those I/O slots. To use slots 3 and 4 requires the second processor. Power supplies Server power is derived from the power supplies installed in the chassis. There are no server options regarding power supplies. Integrated virtualization Flex System x440 Compute Node (7917)
  • Page 26: Light Path Diagnostics Panel

    For quick problem determination when located physically at the server, the x440 offers a 3-step guided path: 1. The Fault LED on the front panel 2. The light path diagnostics panel 3. LEDs next to key components on the system board Flex System x440 Compute Node (7917)
  • Page 27: Remote Management

    An over-temperature condition occurred that was critical enough to shut down the server. A memory fault has occurred. The corresponding DIMM error LEDs on the system board are also lit. A fault is detected in the adjacent expansion unit (if installed). Remote management Flex System x440 Compute Node (7917)
  • Page 28: Supported Operating Systems

    Uploading a diskette image to the IMM2 memory and mapping it to the server as a virtual drive Capturing blue-screen errors Supported operating systems Flex System x440 Compute Node (7917)
  • Page 29: Physical Specifications

    Physical specifications Dimensions and weight (approximate): Width: 437 mm (17.2 in.) Height 51 mm (2.0 in.) Depth 493 mm (19.4 in.) Maximum weight: 12.25 kg (27 lbs) Supported environment Flex System x440 Compute Node (7917)
  • Page 30: Warranty Options

    Supported environment The Flex System x440 compute node complies with ASHRAE Class A3 specifications. This is the supported operating environment: Power on: Temperature: 5 - 40 °C (41 - 104 °F) Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8 - 85% relative humidity Maximum dew point: 24 °C (75 °F)
  • Page 31: Regulatory Compliance

    We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding Lenovo holidays. If it is after 1:00 p.m. and it is determined that on-site service is required, the customer can expect the service technician to arrive the morning of the following business day.
  • Page 32: Related Publications And Links

    51318.249, GOST R 51317.3.2, GOST R 51317.3.3 IEC 60950-1 (CB Certificate and CB Test Report) CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3) CISPR 22, Class A TUV-GS (EN60950-1/IEC 60950-1, EK1-ITB2000) Related publications and links Flex System x440 Compute Node (7917)
  • Page 33: Related Product Families

    US Product Announcement: http://ibm.com/common/ssi/cgi-bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS112-099 Flex System x440 Compute Node product page: http://ibm.com/systems/flex/compute-nodes/x86/bto/ Flex System Information Center: http://publib.boulder.ibm.com/infocenter/flexsys/information/index.jsp Flex System x440 Compute Node Installation and Service Guide : http://publib.boulder.ibm.com/infocenter/flexsys/information/topic/com.ibm.acc.7917.doc/printable_doc.html ServerProven for Flex System: http://ibm.com/systems/info/x86servers/serverproven/compat/us/flexsystems.html ServerProven compatibility page for operating system support: http://ibm.com/systems/info/x86servers/serverproven/compat/us/nos/flexmatrix.shtml Flex System Interoperability Guide : http://www.redbooks.ibm.com/fsig...
  • Page 34 Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk.
  • Page 35 Trademarks Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at http://www.lenovo.com/legal/copytrade.html. The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo®...

This manual is also suitable for:

7917

Table of Contents