Appendix A. 910Fs Fusion Splicer Cleaning - Greenlee 910FS Instruction Manual

Optical fiber fusion splicer
Table of Contents

Advertisement

Appendix A. 910FS Fusion Splicer Cleaning

Precautions When Cleaning 910FS and 910CL
Cleaning V-grooves
Refer to Figure 1.
Clean the bottom of the V-groove with an isopropyl alcohol-impregnated lint-free cotton
swab. Remove excess alcohol from the V-groove with a clean, dry lint-free cotton swab.
If the contaminants in the V-groove cannot be removed with an alcohol-impregnated
lint-free cotton swab, use a cleaved fiber end-face to dislodge contaminants from the
bottom of the V-groove. Refer to Figure 2. Repeat cleaning the V-grooves as in Figure 1.
Cleaning Fiber Clamps
Refer to Figure 3.
If contaminants are present on the clamps, proper clamping may not occur, resulting
in poor quality splices. The fiber clamps should be inspected frequently and cleaned
periodically during normal operation. To clean the fiber clamps, do the following:
Clean the surface of the clamps with an alcohol-impregnated lint-free cotton swab.
Remove excess alcohol from the clamps with a clean, dry lint-free cotton swab.
Greenlee / A Textron Company
• Turn off splicer.
• Use only lint-free cotton swabs.
• Use only 99% pure isopropyl alcohol or an approved substitute.
• Do not touch the electrodes.
• Never use compressed air.
• Use the cleaning brush only to clean debris from general working area, never on the
lenses, V-grooves, or mirrors.
V-grooves
Figure 1
(recommended daily)
Cleaning
Swab
(recommended daily)
44
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
910FS Splicer
Cleaved
Fiber
V-grooves
Figure 2