Heating Protection Sleeve

1. Transfer the fiber with protection sleeve from the centering device to the tube heater.
2. Close the tube heater lid.
3. Press
4. Open the tube heater lids and remove the protected fiber from the tube heater. Apply
5. Visually inspect the finished sleeve to verify that no bubbles or debris/dust is present

Cooling Tray

Place the splice into the cooling tray on the back of the 910FS splicer.

Splice-on Connectors

The 910FS uses the Greenlee version of splice-on connectors. The 910FS currently
supports SC, LC, FC, and ST versions (both PC and APC finish, where applicable).
Follow the instructions supplied with the SOC packaging.
Greenlee / A Textron Company
Notes:
• Make sure the splice point is located at the center of the protection sleeve.
• Make sure the strength member in the protection sleeve is placed downward.
• Make sure the fiber is not distorted.
• The splice-on connector must be installed on the right-hand side of the splicer
heater. Use heater profile #1 for the SOC.
to start tube heating. The beeper sounds and the HEAT LED (red color)
turns off when tube heating is completed.
some tension to the fiber while removing it from the tube heater.
in the sleeve.