The settings below are shown for the top batch on a single brewer top left button on a twin brewer.
See how to access all A menus on the previous page. Below are the brew settings for default A1 & A2 batches
POSITION
Program Items
A11
Batch Volume
A12
Brew Time
A13
Prewet Perc.
Prewet Delay
A14
(Pause after prewet
completes)
A15
This is a
Drip Delay
Safety
Feature
BATCH ACT
A20
A20 YES -
A21
Batch Volume
A22
Brew Time
A23
Prewet Perc.
Prewet Delay
A24
(Pause after prewet
completes)
A25
This is a
Drip Delay
Safety
Feature
Copy From Batch
Batch Copy
Copy To Batch?
Single Topmost Batch cannot be disabled. TWIN Topmost Batch LEFT & RIGHT cannot be disabled.
Middle and bottom batches may be disabled for single and twin brewer (CBS-1131 XV+ and CBS-1132 XV+)
† DRIP DELAY will not activate when STOP is pressed within 5 seconds of starting a brew time
.
RECIPE Location map
Viewing and changing settings for the brew
recipes is from the "A" screens with the controls
in PROGRAMMING.
The uppermost button positions are permanent
and will not display programming step A_0. The
table above shows in position A20 that a button
position can be made active or inactive.
Position A1 does not display this step
Go to fetco.com for the latest versions of all information
Factory set
Default
0.80gal
3.00liters
4:00 minutes
0%
0% [1:00 Min]
1:30 mm:ss
YES
(Active)
NO +
0.80gal
3.00liters
4:00 minutes
0%
0% [1:00 Min]
1:30 mm:ss
A71
A72
Menu Features: Batch Parameters
Increment
Programming Range
0.25 to 1.25 gal
0.95 to 4.70L
2:00 – 12:00
0.00 – 15.0%
[0:10 – 5:00]
0:30 – 6:00 Min.
Middle and Bottom
Batch on
batches A2,3,5,6
0.25 to 1.25 gal
0.95 to 4.70L
2:00 – 12:00
0.00 – 15.0%
[0:10 – 5:00]
0:30 – 6:00 Min.
A71 1 (1-6)
A72.1 (1-6)
DISPLAY
Single Side Models
CBS-1131 XV+
STOP
STOP
BATCH A1
A1
(permanent)
A2
BATCH A2
A3
BATCH A3
User Guide & Operator instructions
Page 6
Notes
s
0.01G
Unit software is in liters;
0.05L
converts to gallon
Default total brew time is
0.30
5:30 minutes
Percentage of total brew
1%
volume
The time between
prewetting and start of
1:00 min
brew cycle.
This feature appears
ONLY if Prewet >0:00
Time that brew basket
remains locked during final
drip-out
Drip delay remains "ON"
for 1:30 minutes if STOP
is pressed during brew†
Batches may be
individually enabled,
or off
rewritten or deactivated
0.01G
Unit software is in liters;
0.05L
converts to gallon
Default total brew time is
0.30
5:30 minutes
Percentage of total brew
1%
volume
The time between
prewetting and start of
1:00 min
brew cycle.
This feature appears
ONLY if Prewet >0:00
Time that brew basket
remains locked during final
drip-out
Drip delay remains "ON"
for 1:30 minutes if STOP
is pressed during brew†
Dual Side Models
CBS-1132 XV+
STOP
STOP
A1
A4
A2
A5
A3
A6
P166
Re0
DISPLAY
BATCH A4
(permanent)
BATCH A5
BATCH A6
NOVEMBER 2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-1132-xv+Extractor cbs-1130 v+ seriesExtractor cbs-1131-xv+Extractor cbs-1132-xv+

Table of Contents