Time Of Day Output - Symmetricom TimeSource 3000 Manual

Gps primary reference source
Hide thumbs Also See for TimeSource 3000:
Table of Contents

Advertisement

S
S
S
S
S
S
Table D. TOD Connector Pinouts
Pin
1
1 pps A
2
1 pps B
3
12 V power source
4
Receive data B
5
Receive data A
6
Circuit ground
7
Transmit data A
8
Transmit data B
72
TimeSource 3000
S
S
S
S
S
S

Time of Day Output

If using time of day (TOD) output, connect the TOD output at the
RJ-45 connector labeled TOD. See Warning: for the connector
location, and Table D for the connector pinouts.
Signal
Note: Pins not listed are reserved for future use.
If the device receiving the time code (for example, Cisco router)
accepts an RS-232 cable instead of an RS-422 cable, follow
Procedure E to install the RJ-45–to–DB-25 TOD converter.
Note:
Before performing Procedure E, ensure that the appropriate
Cisco router or NTP Type 4 compatible device is installed, and
power applied, per manufacturer's instructions.
S
S
S
S
S
S
Abbreviation
TOD PPS +
TOD PPS –
TOD P12V
TOD RXD –
TOD RXD +
TOD GND
TOD TXD +
TOD TXD –
S
S
S
S
S
S
Direction
From TimeSource 3000
From TimeSource 3000
To TimeSource 3000
To TimeSource 3000
From TimeSource 3000
From TimeSource 3000
S
S
S
S
S