F
eatures and benefits

Longer life of battery

The following innovative systems extend the battery's life approx.50% longer.
1. Conditioning charge
The charger receives distinctive data (temperature, history of usage ect.)
from built-in memory chip installed in battery, and decides the most suitable conditions to charge the battery.
The conditioning charge will start, when the battery is employed repeatedly under the following conditions,
which have bad influence on battery's life.
1. Charge under high room temperature (higher than 40°C)
2. Charge under low room temperature (lower than 10°C)
3. Recharge for full charged battery
4. Over discharge (continue to discharge battery in spite of machine's power down.)
Even if the cooling system does not work (because of breakdown of fan or obstruction of vent etc.),
the conditioning charge functions and starts to charge selecting the most friendly method to the battery.
2. Cooling system
The cooling fan prevents the over heat on battery and keep the optimum temperature for charging.
3. The charging control system
This system controls the output current depending on the temperature on the battery in charging process.

Charging light

Charging lights
Chargeable for 7.2V - 24V
batteries
Mark
Two green lights flash, when the charger
is connected to the power source.
One red light is on, when the battery
cartridge is inserted into the charger.
Two red lights are on.
Two green lights are on,
Two red lights flash,
One red light flashes.
Red and green lights flash alternately.
One yellow light is on
One yellow light flashes.
Charging light indicating charging
process and charging condition
with red, green and yellow
Condition
Stand by to charge.
indicating the charged condition in 0 - 79%.
indicating the charged condition
in more than 80%.
Finish of charge.
Cooling the inserted battery.
Its temperature is higher than 70°C.
The charge is stopped until the battery is cooled.
Cooling the inserted battery.
Its temperature is lower than 70°C.
The charge is stopped until the battery is cooled.
Impossible to charge, because
* the life of battery is over.
or
* the vent on charger or battery is clogged.
Conditioning charge is started.
The charging time can be longer than usual.
Breakage on cooling system
(The vent of charger or battery is clogged, or
the cooling fan is damaged.)