Lennox XC20-036-230-01 Installation And Service Procedure page 58

Elite xc20 series
Table of Contents

Advertisement

Table 11. Outdoor Control 7-Segment Display Alert Codes - Compressor
System fault and lockout codes take precedence over system status codes (cooling, heating operating percentages or defrost/dehumidification). Only
the latest active fault or lockout codes are displayed (if present). If no fault or lockout codes are active, then system status codes are displayed. Alert
codes are also displayed on the iComfort Wi-Fi
Inverter LED Flash
Code (number of
Alert
Inverter
Code
Codes
Red LED
E 440
13
1 flash
E 441
14
1 flash
E 600
N/A
N/A
XC20
®
thermostat..
Priority
flashes)
Green LED
3 flashes
Moderate
4 flashes
Moderate
N/A
Critical
Alarm Description
Heat sink temperat­
ure is approaching
limit.
The
com­
pressor speed auto­
Issue: Feedback from supplier tear down of inverter indicates
matically slows to
that the screws that hold the inverter to the inverter board were
reduce heat
sink
loose causing poor contact between these two components.
temperature.
The
control sets indoor
Corrective action: Tighten screws that hold the heat sink to the
CFM and outdoor
inverter control board.
RPM to values ac­
NOTE: Wait 5 minutes to all capacitor to discharge before check­
cording to demand
ing screws.
percentage
rather
than the actual Hz.
Alarm is automatic­
ally cleared.
Compressor
slow­
down due to high
compressor current.
Compressor current
is approaching limit.
The
compressor
Issue: Possible issue is system running at high pressures.
speed automatically
Check for high pressure trips or other alert codes in room ther­
slows. The control
sets indoor CFM
mostat and outdoor control.
and outdoor RPM to
values according to
demand percentage
rather than the actu­
al Hz. Alarm is auto­
matically cleared..
Compressor
has
Load-shedding function: Provides a method for a local utility
been cycled OFF by
company to limit the maximum power level usage of the outdoor
utility load-shedding
unit. The feature is activated by applying 24 volts AC power to
function.
the L and C terminals on the outdoor control.
58
Possible Causes and Clearing Alarm