Honeywell MultiPro Manual page 14

Multi-sensor gas detector
Table of Contents

Advertisement

The sensor screen and instrument serial
number screen will then be shown.
If the MultiPro is equipped with a fully enabled
datalogger, the following screen will be
shown. The time figure in the upper right
corner indicates the sampling interval in
minutes and seconds. Instruments without a
fully enabled datalogger will show display "not
a datalog"
In the MultiPro, the standard one-minute
sampling interval will result in the ability to
store a minimum of 41 hours of readings
before the oldest data is overwritten by new
data. The sampling interval may be modified
using BioTrak Software.
The time will then be shown followed by the
date:
The instrument will display "Self Test" as it
performs operational checks. During the self-
test, the MultiPro tests for installed sensors,
performs a system memory check and tests to
see if a motorized pump is attached to the
instrument. If a pump is detected, it will be
briefly activated during the self-test. For
details on start up procedures for MultiPro
instruments equipped with a pump see section
2.1.1 below.
For instructions on changing the time and
date with the MODE button, see section 6
below.
The instrument temperature will then be
shown.
or
The warning alarm levels screen will then be
shown followed by the danger, STEL and
TWA alarm levels screens.
For more information concerning STEL
and TWA alarms, see sections 2.4.3 and
2.4.4.
After the alarm screens, the calibration due
screen will be shown with the number of days
until the next calibration. The instrument will
then proceed to the current gas readings
screen. If calibration is due, "Cal due now"
will be shown followed by "needs cal". The
user will need to acknowledge the message
by pressing the MODE button. Once the
MODE button is pressed, the MultiPro will
continue to the current gas readings screen
and the appropriate calibration due icon will
blink every 5 seconds to remind the use that
the instrument is past due for calibration.
If the Bump Test Interval setting is enabled,
the bump interval screen will be shown. The
bump due status will be shown in days or
hours.
Note: The Bump Test Interval and bump
test due reminder are used exclusively
with the MultiPro IQ Express Dock.