Step 2: hold the handle in the upper front panel of the power supply module, and
draw out the power supply module firmly and smoothly
Step 3: Use a new power supply module and replace the failed module
Step 4: Tighten the panel fasteners in the font panel
Step 5: Successful replacement will be indicated by the green Power OK indicator
being illuminated and by the yellow Fail indicator not illuminating.
Installation of a power supply module is shown below:
FIG 2-10 The installation and removal of DCRS-7608 power supply modules
Clean power module dust gauze:
Power module dust gauze is provided in the front panel of the MRS-PWR-B1-AC and
MRS- PWR-B1-DC power modules, which can be removed and installed easily. It can
prevent large debris or particles in the air from being ingested into the power supply
module. Please perform cleaning on a regular basis according to the site conditions.
Pulling the lower dust gauze front panel, draw the dust gauze and front panel
out
Clean the dust gauze with a brush (never wash with any liquid)
Insert the gauze back to its original position in the power supply module