Dcrs-7600 series chassis core routing switch
Table of Contents

Advertisement

DCRS-7600 InstallManual
DCRS-7608 uses 2 +1 redundant power supplies, three power modules can act as
backups for each other. During normal operation, all three power modules each take one
third of the load. If one of the modules fails or is not present, the other two power modules
will supply power for the whole switch, and the corresponding POWER/Fail warning
indicator for the failed/missing module will illuminate, prompting the replacement of the
failed module. The warning indicator will turn off after the failed module is replaced or
recovers.
The DCRS-7608 power module is installed in the lower section of the chassis, and
connects to the power board of the switch. All the power modules attach to the chassis
with 2 screws, respectively. When replacing the power modules, the chassis need not to
be opened, just remove the 2 fastening screws to take out the power module requiring
replacement.
1.4.4.4.1 MRS-PWR-B1-AC (Alternating Current Power Module)
When powered by AC inputs, the AC power module MRS-PWR-B1-AC and
corresponding AC distribution box should be used in the DCRS-7608. The input voltage of
the MRS-PWR-B1-AC is 110V/220 VAC, with ranges between 90 ~ 264 VAC and
frequency between 50 ~ 60 Hz, the maximum output power is 600W.
1.4.4.4.2 1.4.3.2.2 Power module Front Panel
There are vents (with dust gauzes), 2 fastening screws and handle for replacing the
modules on the front panels of MRS-PWR-B1-AC and MRS-PWR-B1-DC.
The Front Panel view is shown below:
Fig 1-34 MRS-PWR-B1-AC Front Panel view
1-53
Chapter 1 Product Overview

Advertisement

Table of Contents
loading

Related Products for Digital China Networks DCRS-7604

This manual is also suitable for:

Dcrs-7608

Table of Contents