Brew Unit - Gaggia Babila Service Manual

Hide thumbs Also See for Babila:
Table of Contents

Advertisement

GAGGIA BABILA
Keyboard
This is the button test page: each beverage corresponds to a box on the display that changes col-
our when the corresponding button is pressed.

Brew Unit

This screen corresponds to the management of the area inside the front hatch.
The meaning of the various fields is as follows:
Operation:
• WORK: if pressed, switches the unit into its work position
• STOP: if pressed, stops the unit instantly
• HOME: if pressed, switches the unit into its Home position
• DREG UP: increases the coffee dregs counter
• DREG DOWN: decreases the coffee dregs counter
Indicators:
• mA: indicates moment by moment the maximum current (in mA)
consumed by the unit when moving. Its value must not exceed 300 mA
• H/W: becomes active (illuminated) when the unit reaches a "Work" position
• Pres: if active, this indicates that the unit is inserted
• DDr: if active, this indicates that the dregs counter is inserted
• Door: if active, this indicates that the front hatch is closed
KEYBOARD
Espr
Coff
Spec
Long
^
^
Press DOWN
Number coffee
dregs
BREW
Work
Home
Stop
DDr
Press DOWN
Capp
Clean
^
o move to the next screen
Max Brew Unit
mA:
10
Dreg-
H/V
Door
o move to the next screen
05 SERVICE MODE
^
L. Ma
Stdby
^
Current
UNIT
0
Dreg+
Pres
4/13