2.1.2 Turning the supply pressure
regulator
The supply pressure regulator can be turned
on its connecting plate to allow the set point
screw to face either up or down.
1. Unscrew both fixing screws and lift the
supply pressure regulator off its connect-
ing plate.
2. Pull the diverting gasket out of the regu-
lator and keep it in this position.
Connecting plate or adapter plate
Supply air input
(Supply) >
Diverting gasket
Front and back view
Supply air input
Regulator outlet (long rubber finger)
Fig. 4 · Turning the supply pressure regulator on its connecting plate or adapter plate
3. Turn the regulator 180 degrees and re-
insert the gasket. In this way, you keep
the bore assignment of the gasket for
supply air input and regulator outlet.
Note: The long rubber finger of the gas-
ket must always point in the direction of
the regulator outlet (reduced supply
pressure).
4. Fasten the regulator onto the connecting
plate.
Regulator facing upward
Regulator facing downward
Diverting gasket
Long rubber finger
always pointing
towards outlet
Supply air input
depending on the
position of the
gasket
Mounting the supply pressure regulator
Fixing screws
Regulator outlet
9