Mounting the supply pressure regulator
3.2.1
Turning the supply pres-
sure regulator
The supply pressure regulator can be turned
on its connecting plate to allow the set point
screw to face either up or down.
1. Unscrew the two fastening screws and lift
the supply pressure regulator off its con-
necting plate.
2. Pull the diverting gasket out of the regu-
lator and keep it in this position.
Connecting plate or adapter plate
Supply air input
(Supply) >
Diverting gasket
Front and back view
Regulator outlet (long rubber finger)
Fig. 4: Turning the supply pressure regulator on its connecting plate or adapter plate
12
Diverting gasket
Long rubber finger
always pointing
towards outlet
Supply air input
3. Turn the regulator 180 degrees and rein-
sert the gasket. In this way, you keep the
bore assignment of the gasket for supply
air input and regulator outlet.
Î The long rubber finger of the gasket must
always point in the direction of the regu-
lator outlet (reduced supply pressure).
4. Fasten the supply pressure regulator onto
the connecting plate.
Regulator facing upward
Regulator facing downward
Fastening screws
Supply air input
depending on the
position of the
gasket
Regulator outlet