European and Australian DC Power Assembly
Procedure 2-6 Assembling a US or European/Australian DC Power
Place the brackets at the desired position on the pole.
1
Adjust the position of the box so that the antenna connectors are positioned vertically. Align the antennas
2
with the N-type connectors on the box and rotate to close.
Insert the cable into the external Ethernet port and tighten the connector to ensure a weatherproof seal.
3
Identify a certified LPS power supply capable of 10.8-14VDC.
4
Locate the custom power cable provided. Attach cable to unit and tighten the connector to ensure a
5
weatherproof seal.
If the cable has 3 wires, (Red/Black/Green-Yellow. Part number 3063357B01), connect RED to Power,
6
Black to Ground and Green-Yellow to Chassis Ground.
OR
If the cable has 4 wires, (Black/White/Red/Green, Part number
Connect the Red wire to power, White wire to Ground, and the Green wire to Chassis Ground.
Device Connectivity Testing in WMS
Use
Procedure 2-6
an infrastructure device has been added or discovered using the Wireless Management System (WMS).
Procedure 2-7 Testing Infrastructure Device Connectivity in WMS
Apply power to the device, the device should be operational in 60 to 120 seconds
1
Obtain the 802.11 MAC addresses for the devices that were recorded in the MAC Address Table earlier
2
in this manual. The address will be in the following format: xx-xx-xx-xx-xx-xx.
Within the Wireless Management System (WMS), select a device or several devices from the Inventory
3
panel.
Right-click and choose the ping selection from the right-click menu.
4
Check for a successful response to the Ping command for each tested device. Each successful response to
5
a ping command will verify connectivity to the device (IAP or MWR).
Repeat steps 1-5 for additional IAP or MWR devices.
6
Device Connectivity Testing without a MiSC
If your wireless network setup does not include a MiSC, you can still test device connectivity by
issuing a PING command from a command prompt. Each successful response to a ping command will
verify connectivity to a device (IAPs or MWRs).
May 2008
to verify device connectivity only after a MiSC has been setup on the network, and
2-13
MOTOMESH DUO 2.1 4300 Users Guide
3071331H01
), Black is not connected.