Resetting the Circuit Breaker
WARNING! To reduce the risk of electrical shock or injury from
moving parts, unplug before servicing or cleaning.
Your vacuum features a circuit breaker to protect the machine
against damage due to a surge in the electrical current.
Electrical surging can be a result of, though not limited to, a
jammed motor fan.
1.
Should your vacuum cleaner experience a jammed
brushroll with the circuit breaker tripping, first turn the
vacuum off and unplug the unit.
2.
Inspect the brushroll by removing the bottom plate and
remove any debris that may be causing the jam.
3.
Reinstall the bottom plate and reset the circuit breaker by
pressing the Circuit Breaker Reset Button.
4.
Plug in the power cord and turn on the vacuum. If
the vacuum fails to turn on, visit an authorized Aerus
location for assistance or call Aerus Customer Service at
800.243.9078 (U.S) and 800.668.0763 (Canada).

Replacing the Squeegee

If your squeegee splits or begins to look worn, simply slide
the worn squeegee from its track and slide a new one into the
track (service #49832). If you have trouble installing the new
squeegee, please visit your nearest authorized Aerus location
or call Aerus Customer Service at 800.243.9078 (U.S) and
800.668.0763 (Canada).
Annual Checkup
To keep your vacuum in peak operating condition, it is
recommended you bring it to an authorized Aerus location for
an annual checkup. The Service Representative will conduct a
comprehensive examination to ensure your vacuum is in top
operating condition.