AQT8 QAM/IP QUICK GUIDE
For QAM SET-UP: https://www.youtube.com/watch?v=FXus4cP7VhQ

STEP 1 - Connect Inputs

Up to 8 terrestrial and/or clear QAM inputs via an 8-Way Splitter are connected to the
1
8VSB/QAM Inputs.
Connect computer #1 with a web browser to the 10/100 CONTROL port directly using the
2
supplied cable.
3
Connect computer #2 with an installed media player (VLC player or equivalent) to a GigE
switch and then connect GigE switch to the Data Out port on the unit.
4
Connect the power cord to the AQT8.
"Off-Air 8VSB" or
"CATV Clear QAM"
4
Power cord
Computer #1

STEP 2 - Login

• Assign "172.16.70.2" as the static IP address for computer #1.
• Enter "172.16.70.1" into your Browser to access the AQT8.
• Login with Username: "Admin" and the password is "pass".
NOTE: The default IP address for the AQT8 Series is "172.16.70.1".
www.blondertongue.com
You may view this guide as an
Instructional Video:
For IP SET-UP: https://www.youtube.com/watch?v=Pib3MSs3l70
8-Way Splitter
1
IP=172.16.70.1
Cable
2
IP=172.16.70.2
GigE Switch
3
Document# 651235800C / Item#6281
*NOTE:
Requires 20dB
Attenuator if
directly
connected to
the TV*
Computer #2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQT8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blonder tongue AQT8

  • Page 1 • Assign “172.16.70.2” as the static IP address for computer #1. • Enter “172.16.70.1” into your Browser to access the AQT8. • Login with Username: “Admin” and the password is “pass”. NOTE: The default IP address for the AQT8 Series is “172.16.70.1”. Document# 651235800C / Item#6281 www.blondertongue.com...
  • Page 2 STEP 3 - Select Inputs Go to the “Input Map” page: Select “Edit” at the top of the IP Output – Input table. Change the input selection pull down to “All”. Select Modulation Mode for all inputs. Default is “8VSB”. For Clear-QAM inputs, select applicable modulation mode.
  • Page 3 STEP 5 - Check SNR Go to the “Status” page: >22 dB SNR for 8VSB; >33 dB for QAM 256 is recommended. (Increase the RF input level as required to achieve the desired SNR). STEP 6 - Configure QAM Output Go to “QAM”...
  • Page 4 STEP 8 - Configure IP Output Go to the “IP Output Config” page: Configure the “Dest IP” and ”Dest port” for each output stream. Coordinate with the IT System Administrator for required IP addresses. Select the encapsulation, “RTP” or “UDP”, based on the receiving unit’s capabilities.

Table of Contents