Power Specification; Mechanical Specification; Table 3-2: Power Specifications; Table 3-3: Mechanical Specifications - Westell Technologies PS71090 User Manual

2w public safety signal booster
Table of Contents

Advertisement

3.2 Power Specification

Parameter
Main Power Input Voltage
Battery / DC Input Voltage
Power Connector
Power Consumption

3.3 Mechanical Specification

Parameter
Size
Connectors
Mounting Type
Enclosure Lock
Heat Dissipation
Finish
©2017 Westell Technologies
1.877.844.4274

Table 3-2: Power Specifications

Specification
110 VAC
24 VDC to 30 VDC
IEC320
<112W Max.

Table 3-3: Mechanical Specifications

Specification
17.7 x 14.1 x 4.7 in
Donor/Coverage Antenna Ports: 4.3-10 (f)
AC Power In
DC (Battery) Power In
Frame Ground
RJ-45 Ethernet-1 (10/100 Base-T)
RJ-45 Ethernet-2 (10/100 Base-T)
9-Pin D-SUB, female
Wall-Mount with 4 holes
Key Lock
Natural Convection
Red color Paint
PS71090 Product Manual
March 2017, Rev G
Note
Internal AC DC Power Supply
External Battery Power Supply
AC/DC
<4 Amps Max.
Note
L x H x D
Matting Male Connector Torque
3.7 ft.-lbs.
AC cord
DC cord
Two-Lug Ground
GUI Interface
SNMP Interface
Alarm Relay Interface
2 holes in each side
Two-Key Lock
WESTELL.COM
March 2017; Doc No. CS14702802UM rG
Page 19 of 50