Process Interface

The Process Interface allows simultaneous analysis of the electrical and mechanical
power of up to four motors (generators). The torque and rotational speed are measured
via frequency inputs or as analog signals.

Pin Assignment

Figure 9-1 shows the Process Interface that is located on the rear panel of the Power
Analyzer (see "Design and Functions" in Chapter 3).
M1+...M4+
M1-...M4-
N1+...N4+
N1-...N4-
D1+...D4+
AGND
A1...A4
Shop for Power Metering products online at:
M 1+
N 1+
D 1+
M 2-
N 2-
M 3+
N 3+
D 3+
M 4-
N 4-
AGND
A 2
A 4
Figure 9-1. Process Interface Pin Assignment
Pin
Four inputs for torque; configurable for analog or digital signals
Four inputs for rotational speed; configurable for analog or digital signals
Four inputs for sensing rotation; only for motor analysis with digital speed inputs;
corresponding inputs, that is N1/D1 share a LO port
Analog ground input
Four analog outputs