Preparation for Use

Before using your WiTouch Pro device, you will need to apply the gel pads to the device and prepare
the device for a treatment.
Applying the Gel Pads to the WiTouch Pro Device
The gel pads are intended for single person use. They will last, depending on skin type, oils, and
pH levels, approximately two to five applications. Replace the gel pads when they no longer adhere
completely. Follow these steps to apply the gel pads:
1. Separate the two gel pads.
2. Remove the blue liner from the side
being applied to the electrode area.
The blue liner can be discarded.
Do not remove the green protective liner.
3. Align the shape of the first gel pad with
the electrode area. Apply the gel pad
onto the electrode area and firmly
press across the entire surface to
ensure good adhesion.
4. Repeat steps 1 – 3 for the second gel pad.

Skin Preparation

• Trim, not shave, excessive hair on
the treatment area.
• Wash the skin and dry completely.
(Do not use alcohol).
Treatment area should be void of oils and/or lotions.
Conducting a Treatment
Always read the Safety information before conducting a treatment. Follow these steps to conduct
a treatment:
IMPORTANT! Do NOT activate stimulation of the device prior to application of the device to the back.
IMPORTANT! In case of emergency, press the ON/OFF button on the device for one (1) second to
power off the device.
1. Remove the green liners from the gel pads by
slowly peeling the liner diagonally from an inside
corner to the opposite outside corner.
IMPORTANT! Avoid contact of the gel pad with other
objects. Contact with other objects may affect the
pads' adhesion properties. Do not discard the green
liners. Save the green liners for storage of the device.
2. Press, and hold, the ON/OFF button on the WiTouch Pro
device for one (1) second. The LED will begin flashing
indicating the device is ready for use and in standby
Note:
mode.
The WiTouch Pro device must always be
ON prior to application.
3. Align the center of the device over the spine and
place the device on your back in the area of pain.
If you cannot place the device properly,
ask another person for assistance.
IMPORTANT! Do not apply the gel
pads/electrodes directly over the spine.
Treatment Recommendations
• You can leave the device in position for
multiple treatments during the day. It will
automatically turn off after two (2) hours
of inactivity.
• It is recommended you wait a minimum
of 30 minutes between treatments.