Installation - Sanitron S2400C Installation Operation & Maintenance

Table of Contents

Advertisement

I
NSTALLATION
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK
1.
Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there
is any damage to the purifier, power cord or plug. SANITRON
Keep the lamp aside for installation once the purifier has been properly installed..
2.
Units occasionally experience damage in shipment due to the fragility of the quartz sleeve. It is, therefore, recommended
to inspect the water purifier for damage to the quartz sleeve after it has been removed from the shipping carton. Each end
of the unit as well as the inlet and outlet should be viewed to see if the quartz sleeve has experienced damage. If the quartz
sleeve shows signs of damage it should be replaced before the purifier is pressurized. See "Quartz Sleeve Installation or
Replacement" in the "Maintenance" section for the proper method of replacing the quartz sleeve in your water purifier.
Note:
Solenoid plugs into the top of the Time Delay,
and the Time Delay into the Ultraviolet Monitor
Incoming
Water
Supply
Note:
Drain Pan
Recommended.
Water purifi er
should be
installed at
minimum of 18"
above fl oor
3.
The water purifier's dual chamber heads are removable and may be rotated independently, which aids in the installation,
maintenance or the retrofitting of an existing system.
4.
The water purifier should be mounted horizontally on a flat dry surface. Secure the water purifier using the mounting holes
in the ballast housing or with the optional wall mounting kit. The purifier should not be solely supported by its plumbing
connections.
6
Figure 2 - Recommended Installation
Cold Water Line
COMMON
PRE-TREATMENT or
PUMPING DEVICES
1. Deionizer
2. Water Softener
3. Carbon Filters (GAC)
5 Micron Filter
4. Pressure Tank
5. Pump
6. Reverse Osmosis
7. Prefilters
Ultraviolet Water Purifiers
should be installed closest
to the point of use. (POU)
12" Manual Wiper
50"
Recommended Minimum Clearance
For Lamp or Quartz Sleeve Removal
Figure 3 - Recommended Installation
Note: DO NOT rotate head so wiper knob is at 12 o'clock position
®
Model S2400C is shipped with the lamp packed separately.
OPTIONAL EQUIPMENT
Two Minute Time Delay
Solenoid Valve
Flow Control Valve
Elbow
OPTIONAL EQUIPMENT
Ultraviolet Monitor
Valve
Audio Alarm
Union
Wall Mounting Kit
OPTIONAL EQUIPMENT
Use of Metal Pipe is recommended for 12"
past elbow to the inlet or from the outlet.
(avoids ultraviolet degradation of exposed plastic pipe)
POINT OF USE
(POU)
Elbow
Ultraviolet Water Purifiers
should be installed closest
to the point of use.
Outlet Line to
point of use
to be as short
as possible
Union
Clearance for
Gland Access
Ultraviolet Water Purifier
Valve
6" Minimum

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S15,000cS20,000cS10,000cS5,000cS25,000c

Table of Contents