Lamp Installation Or Replacement - Sanitron S2400C Installation Operation & Maintenance

Table of Contents

Advertisement

L
I
AMP
NSTALLATION OR
Step 3 - Withdraw Lamp
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK
1.
WARNING: Disconnect power to water purifier.
2.
Remove both EASY-OFF
the socket.
3.
Carefully withdraw lamp approximately 2 inches from chamber while feeding lamp socket and lead wire on opposite end of
chamber.
4.
While holding lamp end, carefully remove lamp socket on end now exposed.
5.
Next, carefully slide lamp back into chamber, until approximately 2 inches of the lamp is exposed on the opposite end. Hold
lamp and remove lamp socket.
6.
Lamp should now be disconnected on both ends. Carefully remove lamp from chamber. Be sure to withdraw lamp straight
out without angling until completely clear of quartz sleeve.
CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when handling.
7.
Reinstall lamp in reverse order.
WARNING: Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to water purifier until
lamp and both EASY-OFF
10
R
EPLACEMENT
Figure 5 - Lamp Replacement
Step 4 & 5 - Remove Sockets
TM
end caps by pulling each cap off static gland nut. Slide each end cap along the wire away from
TM
end caps have been properly reinstalled.
Step 2 - Remove End -Cap
Step 6 - Remove Lamp

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S15,000cS20,000cS10,000cS5,000cS25,000c

Table of Contents