IKA RV 10 basic Operating Instructions Manual

IKA RV 10 basic Operating Instructions Manual

Rotary evaporators
Hide thumbs Also See for RV 10 basic:

Advertisement

36 785 00
IKA®RV 10 basic
042009
Reg.-No. 4343-01
IKA®RV 10 digital
Betriebsanleitung
Operating instructions
Mode d'emploi
Instrucciones de manejo
DE
5
EN
17
FR
29
ES
41

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RV 10 basic and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IKA RV 10 basic

  • Page 1 36 785 00 IKA®RV 10 basic IKA®RV 10 digital Betriebsanleitung Operating instructions Mode d’emploi Instrucciones de manejo 042009 Reg.-No. 4343-01...
  • Page 2: Table Of Contents

    Correct use Maintenance and cleaning Unpacking Accessories Useful information Error codes Setting up Technical data Drive RV 10 basic/ digital Solvent table (excerpt) Heating bath Warranty Glassware Hose system Safety instructions For your protection • Read the operating instructions in full before starting up and •...
  • Page 3: Correct Use

    Correct use • Use The safety of the user cannot be guaranteed if the appliance is ope- Together with the accessories recommended by IKA, the device rated with accessories that are not supplied or recommended by is suitable for: the manufacturer or if the appliance is operated improperly contrary to the manufacturer’s specifications.
  • Page 4: Setting Up

    Setting up ☞ Remove the clamping device for the angle setting of the rotation Drive RV 10 basic/digital drive on the right side of the lift by rotating the knurled screw CAUTION! Loosen transportation lock (fig. 4a)! counter clockwise (by lightly pressing and turning at the same time, the knurled screw comes out farther).
  • Page 5 ☞ Feed the steam pipe in until it stops. Prior to commissioning - Mounting the seal RV 06.15 ☞ Then lock the locking device by turning it clockwise by 60° ☞ Insert vapour tube (1). (fig. 10). ☞ Insert seal RV 06.15 (2). ☞...
  • Page 6: Hose System

    Removing the condenser Hose system ☞ Connect the water hoses to the condenser according to the coun- ☞ Use the ring spanner provided to loosen union nuts that are tightly ter-flow principle (fig. 14). fitted. ☞ Install the vacuum connections to the condenser, Woulff bottle, ☞...
  • Page 7: Interfaces And Outputs

    1.1. The NAMUR commands and the additional specific IKA co m- mands serve only as low level commands for communication between the rotary evaporator and the PC. With a suitable ter- Fig.15...
  • Page 8: Commissioning

    Commissioning ☞ Set the target value “Int” on the knob by turning (1 to 60 minu- The unit is ready for service when the tes). mains plug has been plugged in. ☞ Starting the “Int” function - Automatic when rotation drive is running - Start the rotation drive On/Off switch (Fig.
  • Page 9: Maintenance And Cleaning

    ☞ Lower the lift by holding down the “M” key. Note: If non-original accessories are used that are not supplied by IKA, then it is possible that the 50 mm travel range provided by the ☞ The drive stops automatically when the preset desired lower end heating bath will not be sufficient.
  • Page 10: Accessories

    Accessories RV 10.1 NS 29/32 Vertical glassware (1) RV 10.10 NS 29/32 Vertical glassware, coated (1) RV 10.2 NS 29/32 Diagonal glassware (2) RV 10.20 NS 29/32 Diagonal glassware, coated (2) RV 10.700 NS 29/42 Vertical glassware (1) RV 10.710 NS 29/42 Vertical glassware, coated (1) RV 10.800 NS 29/42 Diagonal glassware (2)
  • Page 11 RV 10.200 KS 35/20 Receiving flask, coated 100 ml RV 10.201 KS 35/20 Receiving flask, coated 250 m RV 10.202 KS 35/20 Receiving flask, coated 500 ml RV 10.203 KS 35/20 Receiving flask, coated 1000 ml RV 10.204 KS 35/20 Receiving flask, coated 2000 ml RV 10.205 KS 35/20 Receiving flask, coated 3000 ml RV10.300...
  • Page 12: Error Codes

    If the actions described fail to resolve the fault or another error code is displayed then take one of the following steps: - Contact the service department, - Send the device for repair, including a short description of the fault. Technical Data RV 10 basic RV 10 digital Operating voltage range 100 - 230 + 10%...
  • Page 13: Solvent Table (Excerpt)

    C 2 H 6 O Warranty In accordance with IKA warranty conditions, the warranty period is The warranty does not cover worn out parts, nor does it apply to 24 months. For claims under the warranty please contact your local faults resulting from improper use, insufficient care or maintenance dealer.

This manual is also suitable for:

Rv 10 digital

Table of Contents

Save PDF