Description
3.2 LED display
LED
L1
P1
R1
F
P1
R1
Note
Primary user (radar) on all enabled channels (only when DFS is enabled)
If the device detects a primary user (for example radar signals) on all enabled channels of
the WLAN interface, the LED F is lit and R1 flashes. No data traffic is then possible for the
next 30 minutes. After this time, the device runs the scan again and checks whether a
primary user still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened
even by restarting the device.
10
Color
Meaning
Green
Power supply L1.
Green
There is a connection via the Ethernet interface (Link).
Green and yel-
Data transfer via the Ethernet interface.
low flashing
alternately
SCALANCE W760 in access point mode:
Green
The WLAN interface is initialized and ready for operation.
SCALANCE W760 in client mode or SCALANCE W720:
There is a connection via the WLAN interface.
Green and yel-
Data transfer over the WLAN interface.
low flashing
alternately
SCALANCE W760 in access point mode:
Green
flashing briefly
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
SCALANCE W760 in client mode or SCALANCE W720:
The client waits for the MAC address due to the setting "Automatic" for
the "MAC mode" parameter and is connected to no access point.
SCALANCE W760 in client mode or SCALANCE W720:
Green
flashing 3 x
The client waits for the MAC address due to the setting "Automatic" for
short, 1 x long
the "MAC mode" parameter and is connected to an access point.
Red
An error occurred during operation with the device.
Red
A primary user was detected on all enabled channels.
R1 flashing yel-
(only when DFS is enabled or according to IEEE 802.11h)
low at the same
time
Flashing yellow
"Flashing" enabled using SIMATIC NET Primary Setup Tool (PST).