April 2017
How to Install and Calibrate the
Level Sensor - Procedure 1
Tip-over hazard. Failure to install
or calibrate the level sensor as
instructed will compromise
machine stability and cause the
machine to tip over, resulting in
death or serious injury. Do not
install or calibrate the level
sensor other than specified in
this procedure.
1
Move the machine to an area that has a firm,
level surface and is free of obstructions.
Note: The surface must be 0° +/- 0.5°.
2
Remove the platform controls from the
platform.
3
Turn the key switch to platform controls and
pull out the red Emergency Stop button to the
on position at both ground and platform
controls.
4
Raise the platform 7 to 8 feet / 2.1 to 2.4 m.
5
Lift the safety arm, move it to the center of the
scissor arm and rotate down to a vertical
position.
6
Lower the platform onto the safety arm.
Crushing hazard. Keep hands
clear of the safety arm when
lowering the platform.
If you are not installing a new level sensor, proceed
to step 15.
Part No. 1272217
7
8
Note: The wire harness connection is located next
to the level sensor, on top of the chassis at the
steer end of the machine.
9
10 Tag and disconnect the level sensor wires
11 Securely install the wires of the new level
GS-30 • GS-32 • GS-46 • GS-47
Service and Repair Manual
Ground Controls
Turn the key switch to the off position and
push in the red Emergency Stop button to the
off position at the ground controls.
Tag and disconnect the level sensor wire
harness from the chassis wire harness.
Remove the level sensor retaining fasteners
and remove the level sensor from the
machine.
from the level sensor connector plug.
sensor into the level sensor connector plug.