Sencor SAC 1811CH User Manual

Sencor SAC 1811CH User Manual

Wall mounted split air conditioner

Advertisement

Wall Mounted Split Air Conditioner
Prior to using this air conditioning device, please read the user's manual thoroughly, even in cases,
when one has already familiarised themselves with previous use of similar types of appliances. Only use
the device in the manner described in this user's manual. Keep the manual for future use.
We recommend saving the original shipping cardboard box, packaging material, receipt and
responsibility statement of the vendor or warranty card for the duration of warranty. In the event of
transportation, we recommend that you pack the air conditioning device using the original packaging
materials only.
Copyright © 2015, Fast ČR, a.s.
User's manual
EN-1
SAC 1811CH
SAC 2411CH
02/2015

Advertisement

Table of Contents
loading

Summary of Contents for Sencor SAC 1811CH

  • Page 1 Wall Mounted Split Air Conditioner User's manual SAC 1811CH SAC 2411CH Prior to using this air conditioning device, please read the user's manual thoroughly, even in cases, when one has already familiarised themselves with previous use of similar types of appliances. Only use the device in the manner described in this user's manual.
  • Page 2: Table Of Contents

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH CONTENTS IMPORTANT SAFETY INSTRUCTIONS ......................3 DESCRIPTION OF THE AIR CONDITIONING DEVICE ..................5 DESCRIPTION OF THE DISPLAY ........................6 DESCRIPTION OF THE REMOTE CONTROL ....................7 AUTOMATIC TIMER CONTROLLED ON/OFF OPERATION ................9 SETTING THE OPERATING MODE, TURBO AND SLEEP FUNCTION ............
  • Page 3: Important Safety Instructions

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH IMPORTANT SAFETY INSTRUCTIONS • This appliance may be used by children 8 years of age and older and by persons with physical or mental impairments or by inexperienced persons if they are properly...
  • Page 4 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH IMPORTANT SAFETY INSTRUCTIONS READ CAREFULLY AND STORE FOR FUTURE USE • Do not install the air conditioning device yourself. Have the air conditioning device installed and commissioned by a specialised company or a qualified technician.
  • Page 5: Description Of The Air Conditioning Device

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH DESCRIPTION OF THE AIR CONDITIONING DEVICE Indoor unit Outdoor unit 1 Filter 7 Air inlet 2 Front panel 8 Connecting pipe 3 Air inlet 9 Water drain hose 4 Horizontal air flow control flaps...
  • Page 6: Description Of The Display

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH DESCRIPTION OF THE DISPLAY 1 Set temperature or timer 4 SLEEP (sleep) mode set indicator 2 COOL (cooling) mode set indicator 5 Automatic start/shut off timer mode set 3 HEAT PUMP (heating) mode set indicator...
  • Page 7: Description Of The Remote Control

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH DESCRIPTION OF THE REMOTE CONTROL EN-7 02/2015 Copyright © 2015, Fast ČR, a.s.
  • Page 8 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH 1 Signal transmitter Sends signals to the indoor unit. 2 Display Shows the current settings. 3 Temperature setting buttons Press once to increase the temperature setting by 1 °C. Press once to decrease the temperature setting by 1 °C.
  • Page 9: Automatic Timer Controlled On/Off Operation

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH AUTOMATIC TIMER CONTROLLED ON/OFF OPERATION Setting the AUTOMATIC TIMER CONTROLLED ON/OFF OPERATION mode Setting up the automatic shut off mode First check that the air conditioning device is on. Press the TIMER button to activate the automatic shut off settings.
  • Page 10: Setting The Operating Mode, Turbo And Sleep Function

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH SETTING THE OPERATING MODE AUTO mode (automatic mode) In this mode the air conditioner automatically adjusts the temperature setting to achieve the most optimal room temperature. After being turned on, the air conditioner will automatically select an operating mode based on the room temperature.
  • Page 11 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH SLEEP mode (sleep) SLEEP mode Press the SLEEP button once to set the SLEEP mode. 7.1.1 If the air conditioning unit is running in the cooling or drying mode, the fan in the indoor unit will be set to low speed.
  • Page 12 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH SLEEP 2 mode Press the SLEEP button three times to set the SLEEP 2 mode. 7.3.1 If the air conditioning unit is running in the cooling or drying mode and the temperature is set in the range 16-23 °C then during the first three hours of the SLEEP 2 mode the temperature will...
  • Page 13: Tilting The Horizontal Air Flow Direction Adjustment Flaps

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH 7.4.4 If the air conditioning unit is running in the heating mode (only on models with a heat pump) and the temperature is set in the range 16-18 °C then the air conditioning unit will continue running at the set temperature.
  • Page 14: Emergency Operation Button

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH EMERGENCY OPERATION BUTTON Use the emergency operation button in the event that the battery in the remote control goes flat or if the remote control malfunctions. 1 Emergency operation button...
  • Page 15: Cleaning And Maintenance

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH CLEANING AND MAINTENANCE • Turn off the air conditioning device and disengage the respective circuit breaker before cleaning. • Clean the front panel and filters in the indoor unit regularly, i.e. at least once every two weeks.
  • Page 16 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH Before putting the air conditioner out of operation for an extended period of time Set the fan to run non-stop for several hours so that the unit is completely dry inside.
  • Page 17: Troubleshooting

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH TROUBLESHOOTING The following table is a troubleshooting guide. If you are unable to remedy the problem with the help of the following table, please contact a service centre. Problem Analysis of the problem The air conditioning unit is not working.
  • Page 18 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH Problem Analysis of the problem In the heating mode (only for models with a heat • This process takes a maximum of 10 minutes. If pump) the indoor fan stops.
  • Page 19: Technical Parameters

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH TECHNICAL PARAMETERS Mono-split air conditioning unit Model number SAC 2411CH Cooling function Average heating season Heating function Hotter season Colder season Design load Seasonal efficiency Item Mark Value Unit Item...
  • Page 20 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH El. power input in modes other than "active mode" Annual power consumption Turned off 0.001 Cooling kWh/year state Stand-by 0.001 Heating/ 1607 kWh/year mode average Thermostat 0.061 in turned off...
  • Page 21 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH Mono-split air conditioning unit Model number SAC 1811CH Cooling function Average heating season Heating function Hotter season Colder season Design load Seasonal efficiency Item Mark Value Unit Item Mark Value...
  • Page 22 1 pW. The declared noise emission level of the indoor/outdoor unit of the air conditioning device SAC 1811CH is 55/64 dB(A), which represents level A of acoustic power with respect to a reference acoustic power of 1 pW.
  • Page 23: Installation Instructions

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH 3. Range of operating temperatures: Maximum cooling Minimum cooling Maximum heating Minimum heating Inside DT/WT (°C) 32/23 21/15 27/-- 20/-- Outdoors DT/WT 43/26 21/15 24/18 –5/–6 (°C) 4. The electrical installation wiring diagram of the air conditioning device (for the indoor/ outdoor units) is supplied with the device.
  • Page 24: Illustration Of The Installation

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH ILLUSTRATION OF THE INSTALLATION Indoor unit Marking out the installation location using the mounting plate of the indoor unit. The connecting pipe may Note: lead from the rear, the The drain hose must...
  • Page 25: Installing The Indoor Unit

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH INSTALLING THE INDOOR UNIT Installing the mounting plate Attach a string to the min. 250 mm middle hole from the ceiling min. 105 mm min. 155 mm from an adjacent wall...
  • Page 26: Electrical Connection Of The Outdoor Unit

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH ELECTRICAL CONNECTION OF THE OUTDOOR UNIT Model with a cooling capacity of up to 6 kW Model with a cooling capacity of over 6 kW 1 Terminal of the outdoor unit...
  • Page 27 Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH O – Model with a cooling capacity of 6.8 kW 2 3 4 Model with Only for the model Model with a heat pump a heat pump with cooling Only for the model...
  • Page 28: Instructions And Information Regarding The Disposal Of Used Packaging Materials

    Wall Mounted Split Air Conditioner SAC 1811CH / SAC 2411CH INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING MATERIALS Dispose of packaging material at a public waste disposal site. DISPOSAL OF USED BATTERIES Batteries contain environmentally damaging compounds and therefore do not belong in standard household waste.

This manual is also suitable for:

Sac 2411ch

Table of Contents