Porter-Cable C3001 Instruction Manual
Porter-Cable C3001 Instruction Manual

Porter-Cable C3001 Instruction Manual

Side stack compressor

Advertisement

Available languages

Available languages

Quick Links

Instruction
manual
MODEL
C3001
To learn more about Porter-Cable
visit our website at:
http://www.porter-cable.com
PROFESSIONAL POWER TOOLS
Copyright © 2004 Porter-Cable Corporation
ESPAÑOL: PÁGINA 17
FRANÇAISE : PAGE 33
Side Stack
Compressor
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No. _______________________________________
Part No. A02492-043-1

Advertisement

Table of Contents
loading

Summary of Contents for Porter-Cable C3001

  • Page 1 Instruction manual MODEL C3001 To learn more about Porter-Cable visit our website at: http://www.porter-cable.com PROFESSIONAL POWER TOOLS Copyright © 2004 Porter-Cable Corporation ESPAÑOL: PÁGINA 17 FRANÇAISE : PAGE 33 Side Stack Compressor IMPORTANT Please make certain that the person who is...
  • Page 2: Safety Guidelines - Definitions

    SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. WARNING: Risk of explosion or fire What Could Happen It is normal for electrical contacts within the motor and pressure switch to spark.
  • Page 4 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
  • Page 5 WARNING: Risk of Electrical Shock What Could Happen Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
  • Page 6 WARNING: Risk of Burns What Could Happen Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. WARNING: Risk from Moving Parts What Could Happen Moving parts such as the pulley, flywheel, and belt can cause serious injury if they come into contact with you or your clothing.
  • Page 7 WARNING: Risk of Unsafe Operation What Could Happen Unsafe operation of your air compressor could lead to serious injury or death to you or others. SAVE THESE INSTRUCTIONS HAZARD...
  • Page 8: Specifications

    DUTY CYCLE 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour. ACCESSORIES 8 - ENG C3001 1.875" 1.250" 15 amps Time Delay 120 PSIG 150 PSIG...
  • Page 9: Installation

    Unpacking Remove unit from carton and discard all packaging. HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
  • Page 10: Extension Cords

    Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end.
  • Page 11: Know Your Air Compressor

    "cut-out" pressure. Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out"...
  • Page 12: How To Use Your Unit

    This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. Make sure the On/Auto/Off lever is in the "OFF"...
  • Page 13: Before Each Start-Up

    Before Each Start-Up: Place On/Auto/Off lever to "OFF". Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero. Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.
  • Page 14: To Drain Tank

    When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 15 Before you store the air compressor, make sure you do the following: Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. Set the On/Auto/Off lever to "OFF" and unplug unit. Turn the regulator counterclockwise and set the outlet pressure to zero.
  • Page 16: Limited Warranty

    • Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s). • Deliver or ship the product to the nearest Porter-Cable Authorized Warranty Service Center. Freight costs, if any, must be paid by the purchaser.
  • Page 17 C3001 Pour de plus amples renseignements concernant Porter-Cable, consultez notre Website à l’adresse suivante : http://www.porter-cable.com PROFESSIONAL POWER TOOLS Copyright © 2004 Porter-Cable Corporation ENGLISH: PAGE 1 ESPAÑOL: PÁGINA 17 Compresseur à pile latérale IMPORTANT Veuillez vous assurer que la personne qui...
  • Page 18: Mesures De Sécurité - Définitions

    MESURES DE SÉCURITÉ - DÉFINITIONS Ce guide contient des renseignements importants que vous deviez bien saisir. Cette information porte sur VOTRE SÉCURITÉ et sur LA PRÉVENTION DE PROBLÈMES D'ÉQUIPEMENT. Afin de vous aider à identifier cette information, nous avons utilisé les symboles ci-dessous.
  • Page 19 CONSIGNES DE SÉCURITÉ IMPORTANTES Un emploi ou un entretien non appropriés de ce produit peut causer des blessures graves et des dommages à la propriété. Lire attentivement tous les avertissements et les directives d'utilisation avant d'utiliser cet appareil. AVERTISSEMENT : Risque d'explosion ou d'incendie Risque Les étincelles qui proviennent des contacts électriques du moteur et du manostat sont...
  • Page 20 AVERTISSEMENT : Risque d'éclatement Réservoir d'air : Les conditions suivantes peuvent affaiblir les parois du réservoir et provoquer une explosion violente du réservoir qui risque de causer des dommages à la propriété ou des blessures graves. Risque Le défaut de vidanger de façon appropriée l'eau condensée dans le réservoir risque de causer la rouille et l'amincissement des parois en acier du réservoir.
  • Page 21 AVERTISSEMENT : Risque de choc électrique Risque Votre compresseur d'air est alimenté par électricité. Comme avec tous les appareils électriques, si l'appareil n'est pas utilisé de façon appropriée, il peut causer des chocs électriques. Toute réparation effectuée par une personne non qualifiée peut entraîner des blessures graves ou la mort par électrocution.
  • Page 22 AVERTISSEMENT : Risque de brûlures Risque Le fait de toucher aux surfaces de métal exposées telles que la tête du compresseur ou les tubes de sortie peut causer de graves brûlures à la peau. AVERTISSEMENT : Risque relié aux pièces mobiles Risque Les pièces mobiles telles que la poulie, le volant-moteur et la courroie peuvent entraîner...
  • Page 23 AVERTISSEMENT : Risque de dommages à la propriété pendant le transport du compresseur (incendie, inhalation, dommages aux surfaces du véhicule) Risque Des fuites ou des déversements d'huile peuvent se produire et entraîner des risques d'incendie, ou des problèmes aux voies respiratoires, des blessures graves ou la mort.
  • Page 24: Cycle De Service

    30 à 45 minutes dans une heure particulière. ACCESSOIRES 40 - FR C3001 1,875 po (4,8 cm) 1,250 po (3,2 cm) 15 a À retardement 4 (15,1)
  • Page 25 Déballage Retirez l'appareil de sa boîte et jetez tout l'emballage. MONTAGE DE L'APPAREIL Emplacement du compresseur d'air Le compresseur d'air doit être situé dans un endroit propre, sec et bien aéré. Le compresseur d'air devrait être situé à une distance d'au moins 12 po (30 cm) de tout mur ou autre obstruction qui pourrait bloquer le débit d'air.
  • Page 26 Rallonges L'utilisation d'une rallonge électrique est déconseillée. L'utilisation d'une rallonge produira une chute de tension qui entraînera une perte de puissance au moteur ainsi qu'une surchauffe. Au lieu d'utiliser une rallonge électrique, augmentez plutôt la longueur du boyau d'air en connectant un autre boyau à l'extrémité.
  • Page 27 Familiarisez-vous avec votre compresseur d'air LISEZ CE GUIDE DE L'UTILISATEUR ET TOUTES LES MESURES DE SÉCURITÉ AVANT D'UTILISER CET APPAREIL. Comparez les illustrations à votre appareil pour vous familiariser avec l'emplacement des commandes et boutons de réglage. Conservez ce guide pour références ultérieures. Interrupteur «On/Auto/Off»...
  • Page 28 Système de refroidissement (non illustré) : Le compresseur d'air est doté d'un système de refroidissement d'avant garde. Le cœur de ce système est un ventilateur à technologie avancée. Il est tout à fait normal que ce ventilateur souffle de l'air au-dessus de la tête de la pompe, le manchon du cylindre et le carter.
  • Page 29: Entretien

    Avant chaque mise en marche : Placez le levier «On/Auto/Off» à la position «OFF». Tirez le bouton du régulateur et tournez-le dans le sens contraire des aiguilles d'une montre jusqu'à ce qu'il s'arrête. Poussez le bouton pour le verrouiller. Raccordez le boyau et les accessoires.
  • Page 30: Entretien Et Réglages

    Vidange du réservoir Réglez le levier marche/automatique/arrêt «On/Auto/Off» à la position d'arrêt «OFF». Tirez le bouton du régulateur et tournez- le dans le sens contraire des aiguilles d'une montre jusqu'à ce qu'il s'arrête. Poussez le bouton pour le verrouiller. Enlevez l'outil pneumatique ou l'accessoire.
  • Page 31 Avant de ranger le compresseur d'air, effectuez les étapes suivantes : Revoyez la section intitulée « Entretien » des pages précédentes et exécutez l'entretien requis. Placez le levier « ON/AUTO/OFF » à la position d'arrêt « OFF » et débranchez l'unité. Tournez le régulateur dans le sens contraire des aiguilles d'une montre et réglez la pression de sortie à...
  • Page 32: Garantie Limitée

    • Appliquez tous soins raisonnables lors de l'utilisation et de l'entretien du produit, conformément aux recommandations dans le ou les guide(s) de l'utilisateur. • Livrez ou expédiez le produit au Centre de service après-vente agréé de Porter-Cable le plus proche. Le fret doit, le cas échéant, être acquitté par l'acheteur.