Stacked Washers and Dryers Model LTK96A*N4350 SWD443C Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) Part No. 802128R1 May 2005...
Page 3
IMPORTANT: The electrical installation in the site shall comply with the Australian Electrical Standards, AS3000 and designed in accordance with AS/NZS 3350.2.11 and AS/NZS 3350.2.7, SAA wiring rules, and such local regulations that might apply. The gas dryer installation must conform with the local regulations and AS5601 / AG601 “Gas Installations.”...
Table of Replacement Parts ................Installation................... Contents Dimensions and Specifications............. Before You Start ................... Tools ....................Water....................Gas ....................Location ................... Exhaust..................... Electrical ..................Installing the Unit ................. Step 1: Position Unit Near Installation Area........Step 2: Connect Water Fill Hoses ............ 10 Step 3: Connect Drain Hose to Drain Receptacle ......
Installation Dimensions and Specifications 59.7 cm (23.5 in.) 20.3 cm (8 in.) 39.1 cm (15.4 in.) 13.3 cm (5.25 in.) 47.5 cm (18.7 in.) 71.1 cm 68.3 cm 5.1 cm (28 in.) (26.9 in.) (2 in.) SWD704N ELECTRIC MODELS SWD704N *With leveling legs turned into base.
Installation Before You Start Location Place the unit on a solid floor with an adequate air Tools supply. For more detailed information, refer to section For most installations, the basic tools you will need on Location Requirements. are: Exhaust Use rigid metal duct and exhaust the dryer to the outside by the shortest route possible.
Installation Electrical Installing the Unit WASHER ● Step 1: Position Unit Near Installation Refer to serial plate for specific electrical Area requirements. For more detailed information, refer to section on Washer Electrical NOTE: If the unit is delivered on a cold day (below Requirements.
Installation Step 2: Connect Water Fill Hoses NOTE: Refer to section on Water Supply Requirements before connecting water fill hoses. COLD The appliance is to be connected to the water mains using new hose-sets and old hose-sets should not be reused.
Installation Step 3: Connect Drain Hose to Drain Receptacle Remove the drain hose from its shipping position on the rear of the washer by unhooking the hose from the retainer clamp or by removing the shipping tape. WATER Find the instructions, on the following pages, that are MIXING appropriate for your type of drain receptacle VALVE...
Installation Standpipe Installation Sink Installation For this type of installation, use the beaded tie-down Place the drain hose into the standpipe. strap (supplied in accessories bag), or use a large wire Remove the beaded tie-down strap from accessories tie (available from your local hardware store) and bag and place around standpipe and drain hose and secure the drain hose to the cabinet top hinge (refer to tighten strap to hold hose to standpipe.
Installation In-the-Wall Installation Laundry Tub Installation For installations of this type, the drain hose MUST be For this type of installation, the drain hose MUST be secured to one of the inlet hoses using the beaded secured to the stationary tub to prevent hose from tie-down strap from accessories bag.
Installation Step 4: (Gas Dryer Only) Connect Gas 3. Connect to gas supply pipe. Supply Pipe 4. Tighten all connections securely. Turn on gas and check all pipe connections (internal and external) For further assistance, refer to section on Gas for gas leaks with a non-corrosive leak detection Requirements.
Installation Step 5: Connect Dryer Exhaust System For further assistance, refer to sections on Location Requirements and Dryer Exhaust Requirements. WARNING A clothes dryer produces combustible lint. To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors.
Installation Step 6: Position and Level the Unit NOTE: Use of the dispenser drawer or washer or dryer doors as handles in the transportation of the unit may cause damage to the dispenser or doors. WARNING Remove rubber cups from accessories bag and place Units elevated above floor level must be on all four leveling legs.
Installation Step 7: (Washer Only) Remove the Shock Step 8: Wipe Out Inside of Washer Drum Sleeves and Shipping Brace and Dryer Drum Before using the washer and dryer for the first time, IMPORTANT: The shock sleeves and shipping brace use an all-purpose cleaner, or a detergent and water MUST be removed from the washer before operation.
Installation Step 9: Connect the Washer and Dryer to Step 10: Check Installation Electrical Power Refer to Installer Checklist on the back cover and make sure that unit is installed correctly. Refer to sections on Electrical Requirements and connect the washer and dryer to an electrical power Moving Unit to a New Location source.
Installation Heat Source Check WARNING Electric Dryers For personal safety, lower front panel of Close the loading door and start the dryer in a heat dryer must be in place during normal setting (refer to the Operating Instructions supplied operation. with the dryer).
Installation Electrical Requirements WARNING Washer To reduce the risk of an electric shock or (240 Volt, 50 Hertz with 3 Prong Earthing Plug) fire, DO NOT use an extension cord or an adapter to connect the washer to the NOTE: The wiring diagram is located behind the electric power source.
Page 23
Installation 240 VOLT 50 HERTZ 240 VOLT 0 VOLT 50 HERTZ FLW2069N STANDARD 240 VOLT, 50 HERTZ, 3 WIRE EFFECTIVELY EARTHED CIRCUIT FLW2069N Power Cord Earth (Ground) Prong Figure 23 DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT. DO NOT OVERLOAD CIRCUITS! Do not operate both a washer and gas dryer on the same circuit.
Installation Electric Dryer CAUTION NOTE: The wiring diagram is located inside the control hood. If this appliance is supplied from a cord extension set or an electrical portable IMPORTANT: The electrical installation in the site outlet device, the cord extension set or shall comply with the latest edition of Australian electrical portable outlet device must be Electrical Standards, AS3000, SAA wiring rules,...
Installation Gas Dryer CAUTION NOTE: The wiring diagram is located inside the control hood. If this appliance is supplied from a cord extension set or an electrical portable IMPORTANT: The electrical installation in the site outlet device, the cord extension set or shall comply with the latest edition of Australian electrical portable outlet device must be Electrical Standards, AS3000, SAA wiring rules,...
Installation 4. If local codes allow the use of flexible gas tubing, WARNING connect the 3/8 inch NPT (National Pipe Thread) gas connection at the rear of the dryer to the laundry room’s gas line with new flexible Improper connection of the equipment- stainless steel tubing (using design certified earthing conductor can result in a risk of Australian Gas Association connector only).
Page 27
Installation NOTE: The dryer and its individual gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 3.45 kPa (1/2 psig). 6. Check all pipe connections (internal and external) for gas leaks with a soapy solution.
Installation Water Supply Requirements IMPORTANT: Turn off water supply faucets after check-out and demonstration. Owner should turn off water supply whenever there will be an WARNING extended period of non-use. Under certain conditions, hydrogen gas NOTE: Longer fill hoses are available (as optional may be produced in a hot water system that equipment at extra cost) if the hoses (supplied with has not been used for two weeks or more.
Installation Water Pressure Risers Pressure must be a minimum of 138 to a maximum of Risers (or air cushions) may have to be installed if the 827 kPa (20 to 120 pounds per square inch) static pipes knock or pound when flow of water stops. The pressure measured at the faucet.
Installation Location Requirements IMPORTANT: Unless completely assembled, DO NOT slide the unit across the floor. DO NOT slide Select a location with a solid, sturdy and level floor. the unit more than 1.2 meters (4 feet) once the Do not install unit on carpeting, soft tile, pedestal, a leveling legs have been extended, as the legs and the platform or other weakly supported structure.
Installation Dryer Exhaust Requirements May Be Description Kit Part No. Obtained Locally WARNING Exhaust Duct Not Available (10.2 cm [4 in.] Dia.) A clothes dryer produces combustible lint. To reduce the risk of fire and combustion Flexible Metal Duct 521P3 gas accumulation the dryer MUST be (10.2 cm [4 in.] Dia.) exhausted to the outdoors.
Installation Make-Up Air Requirements Exhaust Direction It is important that the laundry room has adequate The dryer can be exhausted to the outdoors through the make-up air for the dryer(s). A dryer exhausts 180 cfm back, left or right of the dryer. EXCEPTION: Gas (measured at back of the dryer) and sufficient make-up dryers cannot be vented out the left side because of air must be supplied to replace the air exhausted by the...
Installation Exhaust System To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood IMPORTANT: Keep exhaust duct as short as with hinged dampers (obtain locally). possible. NOTE: Weather hood should be installed at least NOTE: Be certain old ducts are cleaned before 30.5 cm (12 inches) above the ground.
Installation Exhaust System Maintenance Dryer Airflow The dryer interior and the complete exhaust system Efficient dryer operation requires proper dryer airflow. should be inspected after one year of use and cleaned Proper dryer airflow can be evaluated by measuring if necessary. Inspect and clean exhaust duct every one the static pressure.
Information for Handy Reference Kleenmaid P.O. Box 5560 Maroochydore South QLD 4558 Date Purchased Model Number Serial Number Store Name Store Address Phone Number Service Agency Service Agency Address Phone Number NOTE: Record this information and keep your sales slip. Model and serial numbers are located on the nameplate.
Installer Checklist Fast Track for Installing the Stacked Washer and Dryer (Refer to the manual for more detailed information) • Position Unit Near Area • Position and Level of Installation. the Unit. SWD693N SWD706N SWD706N SWD693N CHECK CHECK • Remove the Shock •...