Summary of Contents for Optimus UP-127M4

  • Page 4: Table Of Contents

    UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers Contents INTRODUCTION ........................5 FRONT VIEW ........................5 REAR VIEW .......................... 6 ATTENUATORS CONNECTION ..................... 11 ONE SECTION BLOCK DIAGRAM ..................12 TECHNICAL SPECIFICATIONS .................... 13 DOCUMENT VERSION TRACKING ..................13 GUARANTEE ........................14...
  • Page 5: Introduction

    Modular UP-247M2, UP-487 amplifiers 1. INTRODUCTION Models UP-67M4, UP-127M4, UP-247M2 and UP-487 are modular amplifiers suitable for use with public address systems, emergency announcements, background music and reproduction of speech, they are remarkably strong and reliable. Models and output power:...
  • Page 6: Rear View

    UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers 3. REAR VIEW Figure 2 (1) SECURITY PAGING AUXILIARY RELAYS The loudspeakers to be connected must have a line transformer. They switched when corresponding priority contacts of the PRIORITY channels are The total connected power will be the sum of activated.
  • Page 7 UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers Figure 4 (4) MAINS FUSE +24V.D.C. Power supply GND 1. Power supply It is located into the lower positive terminal for negative terminal for power supply amplifiers 1, 2, 3 and 4 AMP. 1 base.
  • Page 8 UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers (7) GROUND TERMINAL (8) VENTILATION OUTPUT Do not obstruct this output under no circumstances. There is a fan in the rear panel, always in operation, changing its speed depending on the temperature reached in the equipment.
  • Page 9 UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers (12) PRIORITY CHANNEL AND (13) PROGRAM CHANNEL The two input channels (PROGRAM & PRIORITY) from Figure 9 each amplifier use 4 RJ45 type connectors in parallel 2 to 2. This way, they can provide signal to other power units (see figure 9).
  • Page 10 UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers Figure 11 (14) DIP SWITCHES SHIELD - GND LINK (DIP switches number 1, 2, 3 & 4) These switches allow removing cable shielding from the internal ground of the equipment for each one of the RJ-45 connectors.
  • Page 11: Attenuators Connection

    UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers (15) LED PRI. CONT. SURV. That led indicates whether the Priority contact is supervised or not. When ON means surveillance activated (DIP switch number 9 PRIORITY CONTACT SURVEILLANCE must be ON). 4. ATTENUATORS CONNECTION Figure 13.
  • Page 12: One Section Block Diagram

    UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers 5. ONE SECTION BLOCK DIAGRAM Modular amplifiers. v 2.3...
  • Page 13: Technical Specifications

    UP-67M4, UP-127M4, Modular UP-247M2, UP-487 amplifiers 6. TECHNICAL SPECIFICATIONS UP-487 UP-247M2 UP-127M4 UP-67M4 R.M.S. Output power 1 x 480 W 2 x 240 W 4 x 120 W 4 x 60 W I.H.F. Output power 1 x 585 W 2 x 312 W...
  • Page 14: Guarantee

    In the event that the guarantee No guarantee benefits shall be provided other than those cited here. rights do not apply, OPTIMUS S.A. shall duly inform the client. If, within a In order to claim the guarantee rights, it shall be an essential...