The above stated mattress specifications assist in ensuring the product conforms to HBSW and IEC specifications. Stryker reserves the right to change specifications without notice. Specifications listed are approximate and may vary slightly from unit to unit or by power supply fluctuations.
Note This provides special information to make maintenance easier or important instructions clearer. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
(WEEE), this symbol indicates that the product must not be disposed of as unsorted municipal waste, but should be collected separately. Refer to your local distributor for return and/or collection systems available in your country. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
• If the bed is equipped with the EPIC II ® PLUS option, there is a power save mode. The power save mode is activated after one hour on battery power with no motion release switch activation.
Page 11
Summary of Safety Precautions WARNING (CONTINUED) • Service only by qualified personnel. Refer to the maintenance manual. Verify the power cord is unplugged and the battery power switch (EPIC II ® PLUS option) is turned to the off position before servicing.
• If the optional iBED Awareness system is being used; use of accessories that cover the alert light are not recommended. BATTERY BACKUP OPTION - OPTIONAL INVERTER PROTECTION FEATURES The optional EPIC II ® PLUS inverter has several features to prevent internal damage: Low Battery Voltage - If the battery voltage at the inverter drops below the low voltage cut-off, the inverter will shut off.
• Raise the Back up to approximately 60°. Squeeze the CPR release handle and ensure the Back and Knee will drop with minimal effort. • If the bed is equipped with the EPIC II ® PLUS battery backup option, unplug the power cord from the wall socket.
No tools are required to replace the battery. Unplug the bed power cord from the wall socket and replace the battery. Properly dispose of the old battery in accordance with local regulations. BATTERY CHARGER CIRCUIT BREAKER (EPIC II ® PLUS OPTION) If the battery charger circuit breaker(s) located under the litter on the patient’s head end, left side are tripped, refer to...
_____ Optional accessories intact and working properly. _____ Check labels, as specified in the Operations and Maintenance manuals to ensure legibility, proper adherence and integrity. _____ Fowler functioning properly. Bed Serial Number: Completed by: _______________________________________ Date: _________________ Return To Table of Contents www.stryker.com 2030-809-002 REV D...
SOME CLEANING PRODUCTS ARE CORROSIVE IN NATURE AND MAY CAUSE DAMAGE TO THE PRODUCT IF USED IMPROPERLY. If the products suggested above are used to clean Stryker patient care equipment, measures must be taken to insure the bed is wiped with a damp cloth soaked in clean water and thoroughly dried following cleaning. Failure to properly rinse and dry the bed will leave a corrosive residue on the surface of the bed, possibly causing premature corrosion of critical components.
If DC voltages do not come back, replace the CPU board. E. Check for 120VAC at connector O on the CPU board. If voltage is present, replace the CPU board. Verify bed function and return to service. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 18
2. If motors are not running, check voltage at motor connection. 3. If voltage is present at motor, check capacitors or motors. D. Verify bed function and return to service. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 19
If voltage is not present, replace the CPU board. b. If 120VAC is present, check the capacitor and motor. C. Refer to Fowler Mechanism Customer Guide (2030-009-028). D. Verify bed function and return to service. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 20
Troubleshooting Guide OPTIONAL EPIC II PLUS BATTERY BACKUP TROUBLESHOOTING GUIDE ® This section of the troubleshooting guide includes the battery backup functions. When using this guide, assume the bed is functioning properly when powered by the AC line cord with the exception of the battery charging components.
Power supply board: Battery wire Are all the Non−Zoom Is the Zoom Replace Inverter/ connectors functions working ? working properly? Charger assembly reversal Replace Inverter/ Charger Inverter is Good Zoom is Good assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 22
Is Battery Volage Sufficient? Replace the Batteries (> 26VDC) Plug Bed into Wall Socket (For Charging/Test) Replace the Inverter Is the Battery Voltage / Charger assembly Increasing? Return Bed to Service Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Load cells and cannot recover. ZeroFail Zero Fail error occurs when the system can- Logged Scale, Bed Exit, iBED Awareness not provide a stable zero value for three con- secutive attempts at zeroing the product. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
The message “Scale Calib. Err” will be displayed in the lower status screen window. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 25
This will cause the product to stop all function and product a message screen indicating the error number and the message “Unknown Bed Type - Call Service” Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 26
CalibrationException If the scale calibration routine fails then the Message Motion message “Calibration Error” will be displayed for 4 seconds and then return to the mainte- nance menu. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
The parts and accessories listed on this page are all currently available for purchase. Some of the parts identified on the assembly drawing parts in this manual may not be individually available for purchase. Please call Stryker Customer Service USA: 1-800-327-0770 (Option 2), Canada: 1-888-233-6888 for availability and pricing.
Page 28
Foot End Siderail Switch, Left 2032-030-025 Head End Siderail Switch, Right 2032-030-020 Head End Siderail Switch, Left 2032-030-015 LBS Light Indicator, Right 3004-300-225 LBS Light Indicator, Left 3004-300-230 CPU Board 3003-407-900 Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Electrical System Information STANDARD CPU BOARD = 3002-407-950 / IBED AWARENESS CPU BOARD - 3003-407-900 Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 30
Fowler Pot Wiper 9 VDC Pin 2 (Red) Pin 1 (Black) Nurse Call Backup Battery 12 VDC when Bed Pin 1 (Red) Pin 2 (Black) Bed Exit Beeper Exit is Alarming Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Electrical System Information OPTIONAL EPIC II PLUS INVERTER/CHARGER BOARD - 2030-001-030 ® CONNECTOR POSITIVE VOLTAGE NEGATIVE LED DESCRIPTION LOCATION HDR 4 26 VDC Pin 2 Red Pin 1 Black From Battery - unplugged HDR 1 22 VAC Pin 3 Red...
Electrical System Information OPTIONAL EPIC II PLUS DISPLAY/CPU - 2030-031-910 ® CONNECTOR POSITIVE NEGATIVE VOLTAGE DESCRIPTION LOCATION HDR 1 (H) 0-5 VDC Pin 1 Pin 2 Control Pot Wiper Voltage (with Switch On) Battery voltage Battery Voltage Return from On/Off Switch (with...
Electrical System Information OPTIONAL EPIC II PLUS AC CROSSOVER BOARD - 2040-031-900 ® CONNECTOR POSITIVE NEGATIVE VOLTAGE DESCRIPTION LOCATION AC Input to Board from the Inverter with the Power Cord HDR 5 (A) 120 VAC Pin 4 Pin 1 unplugged...
Electrical System Information BED COMMUNICATIONS TESTER - 3002-045-805 Bed Communications Tester - 3002-045-805 (reference Only) Item Part No Part Name 3002-045-805 BCT Unit 3001-303-825 37-Pin Cable 3002-045-806 Instructions 3000-303-871 9V Battery Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 38
Electrical System Information 37−PIN CONNECTOR STRYKER PENDANT PORT Pin 1 Option 2 Common Pin 2 Read Light Pin 3 Room Light Pin 4 Speaker High Pin 5 Pot Wiper Pin 6 Radio Common Pin 7 Nurse Call Interlock Pin 8 Audio Transfer -...
2 and 3 of the following procedure. Do not place unprotected circuit boards on the floor. All circuit boards to be returned to Stryker Medical should be shipped in the static shielding bags the new boards were shipped in. Static Protection Procedure Unplug the power cord from the wall receptacle.
Push the brake rod through the frame until the brake pedal is clear. Remove the brake pedal. Reverse the above steps to attach the new brake pedal. Note Use Loctite 242 when reinstalling the bolts and torque the bolts to 25 ft-lbs. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
The drive shaft on the new motor probably will have to be turned to be aligned with the coupler. Use a 7/16” open end wrench to turn the drive shaft of the motor. The procedure for lift motor and capacitor removal and replacement is the same for both ends of the bed. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
11. Reverse the above steps to reinstall the lift housing assembly after service is completed. Note The procedure for lift housing removal and replacement is the same for both ends of the bed. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
11. Reverse steps 4 - 8 to install the new pot and pot housing assembly. 12. After installing the new potentiometer, the “burn-in” procedure must be followed. Note Be sure to maintain the potentiometer position while installing. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Up/Down Lock button until the light flashes. CAUTION For both procedures above, do not run the litter all the way down while in the diagnostics mode. Damage to the bottom lift covers could result. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
(C). The motor coupler can now be removed from the lift housing. Reverse the above steps to install the new motor coupler and bushings. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Be sure the clamps are fastened at exactly the correct angle, as shown by the arrows in the illustration. Arrange the cords exactly as shown in the illustration (left in front of right). If this is not done correctly, damage to the cords will result. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 47
Service Information VIEW FROM CENTER OF BED Return To Table of Contents www.stryker.com 2030-809-002 REV D...
12. Reverse steps 1 - 11 to install the new batteries. Complete the last four items of the setup procedures section. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
“ Select Corner”, press one of these buttons to cycle through the corners and to select the load cell assembly at the desired corner. A. ZERO = Cycle up through the four corners B. SCALE ON/OFF = Cycle down through the four corners Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 50
11. Level the bed at a full up or full down position. Remove the weight and zero the bed. 12. Verify scale accuracy and functionality before returning the bed to service. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Press the “Enter/Check” button when the display shows the proper weight. The display should present the following message: “Place Weight in Center”. Place the weight in the center of the bed. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 52
“Do Not Touch Bed”. The message should be flashing. 34. The display should present the following message when the bed is ready to continue: “Press Reverse Trend”. 35. Press the reverse trend button. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 53
The TV Configuration screen should reappear after 2 seconds and the new setting should be highlighted. Pressing the Exit/X button or if the screen remains dormant for more than 30 seconds, the display will return you to the maintenance menu, without saving any changes. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 54
• When the menu item is selected the maximum values for each of the load cells will be displayed. • Values should update every 0.25 seconds. Note: The scale information and statistics are important when trying to diagnose the scale system. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 55
The Maintenance Menu screen should reappear after 2 seconds and the new setting should be highlighted. Note: Items that are cleared during this operation are: • Maximums (for each load cell) • Minimums (for each load cell) Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 56
If “Exit” is chosen, then you will be returned to the Maintenance Menu screen. If “Enter” is chosen, then the error log is cleared and a message is displayed: “Error Log Cleared” and you will be returned to the Maintenance Menu screen. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 57
Exit Maintenance • This feature allows the operator to exit the menu back to the previous screen. • When this menu item is selected the screen will exit to the “Status” screen. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Using a saw horse, support the litter at the end where the load cell was removed. Reverse the above procedure to install the new load cell. Note Scale calibration procedure must be performed after the load cell is replaced (Refer to Scale System Diagnostics and Calibration section). Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Remove the motor mounting bracket from the old motor and install it on the replacement motor. Reverse steps 3 through 6 to install the replacement motor. Verify the bed is working properly before returning it to service. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
12. Pull the foot panel toward the foot end of the bed. This causes the knee motor linkage to roll back past center. If this step is not done, damage to the motor or linkage will occur. 13. Verify the bed is working properly before returning it to service. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Using needle-nose pliers, squeeze the four stand off supporting the power supply and pull up gently on the power supply to remove it. Reverse steps 2 through 5 to install the new power supply. Verify the bed is working properly before returning it to service. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
The Fowler potentiometer should be set at 150Ω (±10Ω) in the full down position. This reading must be taken from pins 3 and 4 on the connector with the potentiometer unplugged from the board. After the correct ohm reading is achieved, tighten the screw on the linkage. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
14. Press and Hold down the Enter button. The message “Release Button” will be displayed on the screen. 15. After releasing button, the message “Fowler Calibration Complete” will be displayed on the screen. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Magnavox (models 9120, 9220, 9320) Seven time Seven flash Traditional Plus Eight time Eight flash Traditional TV Nine time Nine flash Auto Detect: Smart TV Ten time Ten flash Auto Detect W/Digital Volume Smart TV Return To Table of Contents 2030-809-002 REV D www.stryker.com...
TV Config. 2 Zenith 1 TV Config. 3 Zenith 2 TV Config. 4 Philips TV Config. 5 Magnavox TV Config. 6 Traditional Traditional Traditional Plus Traditional Plus Auto-Configure Auto-Configure Auto-Configure DV Auto-Configure DV Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Service Information EPIC II PLUS OPTION AC CROSSOVER BOARD REPLACEMENT (CONTINUED) ® PROCEDURE (CONTINUED): FIGURE 3 Using a #2 Phillips screwdriver, remove the three screws (D) holding the control bar cover to the head end of the bed (see Figure 3).
Page 68
Using a #2 Phillips screwdriver, remove the six screws holding the display/CPU board to the control bar cover and remove the board. Reverse steps 2 & 3 to install the new board. Reverse steps 1 - 8 of the AC Crossover Board replacement procedure on page EPIC II ® PLUS Option AC Crossover Board Replacement section to reassemble the bed.
Reverse the above steps to reattach the cover. CAUTION Do not snag the cables when installing the siderail cover. Note Follow the same procedure for siderail cover removal for the foot end rails. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Note the location of the spacers (C) for reassembly purposes. Pull up on the molded rail (B) to remove it from the siderail assembly. Reverse the above steps to install the new molded rail. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 71
Notes Return To Table of Contents www.stryker.com 2030-809-002 REV D...
No tools are required to replace the battery. Unplug the power cord from the wall socket and replace the bat- tery. After replacing the battery, verify the Power LED is no longer flashing. Dispose of the old battery in accordance with local regulations. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Reverse the above steps to install the new module. CAUTION The modules must be overlapped as shown in the illustration to prevent fluids from entering the board cavity and causing damage. Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Be sure to install the plug with the flat edge (B) at the top left, as shown in the illustration, or the footboard interface plug will not mate properly with the bed and damage to the plug or footboard could result. Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Base Assembly and Options 3002-200-003 (Reference Only) Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 76
20 ± 5 ft - lbs Torque item J to 20 ± 5 ft - lbs Torque item J to 20 ± 5 ft - lbs Torque item J to 20 ± 5 ft - lbs Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 77
Base Assembly and Options Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 78
Base Assembly and Options Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 79
Base Assembly and Options Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 80
Base Assembly and Options Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 81
Steer Cable Retaining Clip 0011-611-000 Washer 0025-191-000 Rivet 3006-200-339 Steer/Swivel Lever Bushing 3006-200-374 Swivel Lever 3006-200-376 Swivel Lock Activation Spring 3006-200-378 Swivel Lock Return Spring, Right 3006-200-379 Swivel Lock Return Spring, Left Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 82
Base Assembly and Options Base Assembly, EPIC II® Bed - 2030-246-003 (Reference Only) Item Part No. Part Name Qty. 0003-333-000 Hex Head Cap Screw 3000-300-002 Plastic Clip Nut 2040-343-200 Zoom Head End Lift Assembly 2040-343-250 Zoom Foot End Lift Assembly...
Page 83
Base Assembly and Options Base Assembly, EPIC II PLUS Steer Option - 2030-999-137 (Reference Only) ® Item Part No. Part Name Qty. 0003-349-000 Hex Head Cap Screw 0025-191-000 Rivet 0023-092-000 Truss Head Phillips Screw 0030-052-000 Snap Bushing 3006-200-380 Steer Extension Spring...
Motor Isolation Plate Assembly - 3001-201-214 Isolation Plate Assembly - 3000-200-723 Item Part No. Part Name Qty. 3001-200-213 Isolation Plate 3000-300-442 Grommet Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Brake Crank Assembly - 3002-201-330 Item Part No. Part Name Qty. 3002-201-309 Brake Cam Shaft Crank 0014-004-000 Washer 3002-200-331 Brake Link 3002-200-332 Dog Leg Brake Link 0002-108-000 Socket Hd. Shoulder Screw Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Part No. Part Name Qty. 0005-018-000 Carriage Bolt 0016-035-000 Nylock Hex Nut 3000-200-318 Guide Pin 3002-200-310 Brake Bar Return Spring 3000-200-324 Brake Bar Bumper 3003-200-323 Brake Bar 3006-200-327 Machine Toothed Brake Ring Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Swivel Lock Caster Assembly, Opal - 2030-200-060 Item Part No. Part Name Qty. 0003-342-000 Hex Head Cap Screw 0016-060-000 Top Lock Locknut 2030-200-059 Caster Horn with Bearing and Swivel 5000-002-010 Molded Wheel Assembly Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Steer Swivel Caster Assembly, Opal - 2030-200-065 Item Part No. Part Name Qty. 0003-342-000 Hex Head Cap Screw 0016-060-000 Top Lock Locknut 2030-200-063 Caster Horn with Bearing and Steer Swivel 5000-002-010 Molded Wheel Assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Base Uni-Pan Cover Assembly - 3002-300-010 Item Part No. Part Name Qty. 0988-002-708 Service Caution Label 3002-300-009 Uni-Pan Cover Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 96
Notes Return To Table of Contents 2030-809-002 REV D www.stryker.com...
EPIC II PLUS, Optional Base Assembly ® 2030-201-210 (Reference Only) Head End Head End Head End Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 98
EPIC II PLUS, Optional Base Assembly ® HEAD END FOOT END HEAD END Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 99
EPIC II ® PLUS, Optional Base Assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 100
EPIC II PLUS, Optional Base Assembly ® Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 101
EPIC II PLUS, Optional Base Assembly ® EPIC II PLUS Optional Base Assembly - 2030-201-210 (Reference Only) ® Item Part No. Part Name Qty. 0003-032-000 Hex Hd. Cap Screw 0004-301-000 Pan Hd. Machine Screw 0005-017-000 Carriage Bolt 0007-052-000 Truss Hd. Torx...
EPIC II ® PLUS, Optional Base Power Assembly - 2030-001-030 Item Part No. Part Name Qty. 0004-263-000 But. Hd. Cap Screw 0012-006-000 Helical Lock Washer 3002-001-017 Charger/Inverter Heat Bracket 3002-001-930 Charger/Inverter Board Return To Table of Contents 2030-809-002 REV D...
Foot End Bottom Cover Assembly - 3001-200-022 Item Part No. Part Name Qty. 3002-001-100 Foot End Bottom Cover 3000-000-039 Grommet Head End Bottom Cover - 2040-001-017 Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Litter Assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 106
Litter Assembly Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 107
Litter Assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 108
Litter Assembly Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 109
Litter Assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 110
Litter Assembly Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 111
Litter Assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 112
Litter Assembly Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 113
Litter Assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 114
Litter Assembly Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 115
Litter Assembly EPIC II Domestic, EPIC II PLUS, and ZOOM Common Litter Components - 2032-231-010 ® ® ® (Reference Only) Item Part No Part Name Qty. Item Part No Part Name Qty. 0003-074-000 Hex Hd. Cap Screw 0059-773-000 Push Spacer 0003-078-000 Hex Hd.
Page 116
Litter Assembly EPIC II ® Domestic, EPIC II ® PLUS, and ZOOM ® Common Litter Components - 2032-231-010 (Continued) (Reference Only) Item Part No Part Name Qty. Item Part No Part Name Qty. 2035-032-096 Ball Screw Cover 0011-063-000 Washer 2035-032-801...
Page 117
Litter Assembly EPIC II ® PLUS/ZOOM ® Litter Components - 2040-132-011 High-Sounding Beeper Option - 2030-030-251 Item Part No. Part Name Qty. Item Part No. Part Name Qty. 0007-058-000 Truss Hd. Torx 3001-508-870 High-Sound Beeper Cable 0013-010-000 Ext. Tooth Lock Washer...
Page 118
5010-080-020 9V Battery Box w/Cable 0052-783-000 U Clip 0030-046-000 Strain Relief 2035-031-806 Head Wall Interface Cable EPIC II® PLUS Head Wall Communication w/Nurse 0059-710-000 Static Cap Call - 2030-030-201 3001-300-007 M/F Screw 5010-080-209 9V Battery Box w/Cable Item Part No.
Page 119
Litter Assembly EPIC II PLUS Head Wall w/Nurse Call and 1 Stryker ® Port - 2030-030-202 Item Part No. Part Name Qty. 0001-087-000 Flat Hd. Mach. Screw 0052-783-000 U Clip 2035-031-806 Head Wall Interface Cable 0059-710-000 Static Cap 2030-031-202 Hd. Wall W/NC & 1 Port...
Page 120
Notes Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Litter Assembly, iBed Awareness Option, Std. Components 2032-331-010 (Reference Only) Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 122
Litter Assembly, iBed Awareness Option, Std. Components Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 123
Litter Assembly, iBed Awareness Option, Std. Components See Detail A Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 124
Litter Assembly, iBed Awareness Option, Std. Components Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 125
Litter Assembly, iBed Awareness Option, Std. Components Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 126
Litter Assembly, iBed Awareness Option, Std. Components Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 127
2030-031-802 Head Pot Extension Cable 2030-031-803 Head Lift Motor Extension 2035-032-805 Cable CPU/Power Supply 2035-020-805 Siderail Limit Switch bypass Cable 2032-300-801 Footboard to CPU Cable, Epic 2032-400-804 CPU to Siderail Cable Return To Table of Contents www.stryker.com 2030-809-002 REV D...
EPIC II PLUS, Optional Litter Assembly ® 2030-031-210 (Reference Only) Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 133
EPIC II PLUS, Optional Litter Assembly ® Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 134
EPIC II PLUS, Optional Litter Assembly ® Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 135
EPIC II PLUS, Optional Litter Assembly ® Epic II PLUS, Optional Litter Assembly - 2030-031-210 (Reference Only) ® Item Part No. Part Name Qty. 0004-142-000 Soc. Hd. Cap Screw 0007-052-000 Truss Hd. Torx 0007-063-000 Truss Hd. Torx 0007-058-000 Truss Hd. Torx...
Page 136
EPIC II ® PLUS, Optional Litter Assembly Epic II ® PLUS, Optional Litter Assembly - 2030-031-210 (Continued) (Reference Only) Item Part No. Part Name Qty. 0059-191-000 On/Off Switch 1550-090-001 Hospital Plug Label 2011-001-104 Danger Label 2030-231-007 EPIC II PLUS Logo Label ®...
Page 137
Qty. 3001-300-007 M/F Screw 3001-300-007 M/F Screw 0030-038-000 Grommet 0030-038-000 Grommet HW Comm. W/NC & 1 Stryker Port - 2030-031-202 HW Comm. W/NC & 2 Stryker Ports - 2030-031-203 Item Part No Part Name Qty. Item Part No Part Name Qty.
2035-432-075 (Reference Only) Actuator Box Cover Assembly - 2035-432-075 (Reference Only) Item Part No. Part Name Qty. 2035-332-075 Main Actuator Box Cover 2035-332-076 Actuator Box Side Cover 0007-058-000 Truss Hd. Torx Return To Table of Contents 2030-809-002 REV D www.stryker.com...
CPR Brake Disc 3001-300-551 CPR Spring Cup 3001-300-563 CPR Brake Spring 3001-300-570 CPR Spring Cup 0003-064-000 Hex Hd. Cap Screw 3000-200-245 Flat Washer 0011-193-000 Heavy Flat Washer 0016-012-000 Nylock Nut 3000-300-138 Wire Tie Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Head End Siderail Assembly 2032-402-105 (Left) (Reference Only) 2032-402-205 (Right) Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 151
Head End Siderail Assembly CARRIER/ARM ASSEMBLY Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 152
Head End Siderail Assembly CARRIER/ARM ASSEMBLY Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 153
Head End Siderail Assembly LEFT HEAD END SIDERAIL WIRE ROUTING Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 154
Head End Siderail Assembly RIGHT HEAD END SIDERAIL WIRE ROUTING Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 155
Inner Arm Cover 2035-020-804 Main Outside Cable, Lt. 2035-020-804 Main Outside Cable, Rt. 2035-020-802 Siderail Cable 2035-020-803 Siderail Cable 3003-402-114 Spring Attachment Pin 3003-402-114 Spring Attachment Pin 0030-040-000 Grommet 0030-010-000 Grommet Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 156
2030-000-301 Label, Standard, NC, Lt. 2030-000-401 Label, Standard, NC, Rt. Standard Siderail W/NC & Comm. - 2030-020-015 Item Part No Part Name Qty. 2035-000-102 Label, Standard, Left Right Outer Siderail Label Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 157
Switch Cap 3001-400-522 Filler Cap 3001-403-831 Speaker with Cable 2035-400-051 Lumbar/TV Module, LH 2035-400-053 Lumbar/TV Module, RH 2035-000-301 Label, Std, NC 2030-000-401 Label, Std, NC 3001-402-804 Cable LH Right Inner Siderail Label Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Head End Siderail Outer Panel Assembly - 2032-400-050 Item Part No. Part Name Qty. 0023-088-000 Hi-Low Tapping Screw 2035-400-102 Outer Panel 3001-400-599 Handle Insert Return To Table of Contents 2030-809-002 REV D www.stryker.com...
3001-400-040 (Left) (Reference Only) 3001-400-045 (Right) Left Side Shown Item Part No. Part Name Qty. 3001-400-101 Left Inner Panel 3001-400-201 Right Inner Panel 3001-400-900 Inner Siderail PCB Assembly 0023-088-000 Hi-Low Tapping Screw Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Timing Link Assembly, Head End, Left - 3003-402-005 Item Part No. Part Name Qty. 0011-377-000 Washer 0011-491-000 Washer 3001-400-501 Siderail Linkage Rivot 3003-401-001 Bushing 3003-402-117 Timing Link 3003-402-127 Arm Weldment - LHF 3003-402-128 Arm Weldment - LHH Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Timing Link Assembly, Head End, Right - 3003-402-010 Item Part No. Part Name Qty. 0011-377-000 Washer 0011-491-000 Washer 3001-400-501 Siderail Linkage Rivot 3003-401-001 Bushing 3003-402-117 Timing Link 3003-402-227 Arm Weldment - RHF 3003-402-228 Arm Weldment - RHH Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Siderail Latch Assembly, Head End, Left - 3002-400-070 Item Part No. Part Name Qty. 0025-086-000 Blind Rivet 0081-317-000 Bronze Bushing 3002-400-501 Latch 3002-400-503 Head End Bypass Plate 3002-400-509 Bypass Bushing Spacer Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Siderail Latch Assembly, Head End, Right - 3002-400-075 Item Part No. Part Name Qty. 0025-086-000 Blind Rivet 0081-317-000 Bronze Bushing 3002-400-501 Latch 3002-400-503 Head End Bypass Plate 3002-400-509 Bypass Bushing Spacer Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Siderail Latch Assembly, Head End, Left - 3003-400-070 Item Part No. Part Name Qty. 0025-086-000 Blind Rivet 0081-317-000 Bronze Bushing 3002-400-501 Latch 3002-400-509 Bypass Bushing Spacer 3003-400-503 Head End Bypass Plate Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Siderail Latch Assembly, Head End, Right - 3003-400-075 Item Part No. Part Name Qty. 0025-086-000 Blind Rivet 0081-317-000 Bronze Bushing 3002-400-501 Latch 3002-400-509 Bypass Bushing Spacer 3003-400-503 Head End Bypass Plate Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Siderail Assembly, iBed Awareness Option, Head End, Left - 2032-403-105 Item Part No. Part Name Qty. 0003-344-000 Hex Head Mounting Screw 2032-030-015 Siderail Switch Assembly, HE, Left 2032-402-105 Siderail Assembly, HE, Left 0011-062-000 Washer Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Siderail Assembly, iBed Awareness Option, Head End, Right - 2032-403-205 Item Part No. Part Name Qty. 0003-344-000 Hex Head Mounting Screw 2032-030-020 Siderail Switch Assembly, HE, Right 2032-402-205 Siderail Assembly, HE, Right 0011-062-000 Washer Return To Table of Contents 2030-809-002 REV D www.stryker.com...
LEFT SHOWN Item Part No. Part Name Qty. 0023-294-000 High-Low Tapping Screw 3003-400-300 Switch Holder, Left 3003-400-400 Switch Holder, Right 3003-400-500 Switch Holder, Spring Blade 2032-400-802 Epic Head, Siderail Switch Cable Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Foot End Siderail Assembly 2032-402-305 (Left) (Reference Only) 2032-402-405 (Right) Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 171
Foot End Siderail Assembly Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 172
Foot End Siderail Assembly (Inside the U.S. and Canada) Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 173
Inner Arm Cover 5000-020-005 Inner Arm Cover 0003-226-000 Hex Washer Head Screw 0003-226-000 Hex Washer Head Screw 3001-400-558 Spacer 3001-400-558 Spacer 3003-400-580 Weldment, FE Support Plate 1 3003-400-580 Weldment, FE Support Plate 1 Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Timing Link Assembly, Foot End, Left - 2032-401-030 Item Part No. Part Name Qty. 0011-377-000 Washer 0011-491-000 Washer 3001-400-501 Siderail Linkage Rivet 3003-400-011 Timing Link 3003-401-327 Arm Weldment - LFH 2032-401-328 Arm Weldment - LFF Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Timing Link Assembly, Foot End, Right - 2032-401-025 Item Part No. Part Name Qty. 0011-377-000 Washer 0011-491-000 Washer 3001-400-501 Siderail Linkage Rivet 3003-400-011 Timing Link 3003-401-427 Arm Weldment - RFH 2032-401-428 Arm Weldment - RFF Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Siderail Release Lever Assembly, Left - 3002-400-055 Item Part No. Part Name Qty. 0004-278-000 Socket But. Hd. Cap Screw 0016-002-000 Hex Nut 3003-503-901 Release Label 3001-400-514 Release Lever Pad 3002-400-510 Release Lever Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Siderail Release Lever Assembly, Right - 3002-400-065 Item Part No. Part Name Qty. 0004-278-000 Socket But. Head Cap Screw 0016-002-000 Hex Nut 3003-503-901 Release Label 3001-400-514 Release Lever Pad 3002-400-510 Release Lever Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Part No. Part Name Qty. 0003-344-000 Hex Head Mounting Screw 2032-030-025 Siderail Switch Assembly, FE, Left 2032-401-305 Siderail Assembly, FE, Left 0011-062-000 Washer 0034-443-000 Cord Clamp 0003-221-000 Hex Washer Head Screw Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Part No. Part Name Qty. 0003-344-000 Hex Head Mounting Screw 2032-030-010 Siderail Switch Assembly, FE, Right 2032-401-405 Siderail Assembly, FE, Right 0011-062-000 Washer 0034-443-000 Cord Clamp 0003-221-000 Hex Washer Head Screw Return To Table of Contents www.stryker.com 2030-809-002 REV D...
LEFT SHOWN Item Part No. Part Name Qty. 0023-294-000 High-Low Tapping Screw 3003-400-300 Switch Holder, Left 3003-400-400 Switch Holder, Right 3003-400-500 Switch Holder, Spring Blade 2032-400-802 Epic Head, Siderail Switch Cable Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Footboard Assembly, No Options - 2030-135-011 Item Part No. Part Name Qty. 3000-500-004 End Module 2035-500-101 Footboard Blank Label 3000-500-027 Blank End Label 3001-500-003 Blank Module 3000-500-026 Blank Module Label Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Footboard Blank Label 3000-500-027 Blank End Label 3001-500-003 Blank Module 2030-000-156 Chaperone II Module Label 3002-508-012 Chaperone II Label 3002-508-800 Zone Control Keypad Cable 3002-508-030 Zone Bed Exit Module 3000-500-026 Blank Module Label Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Part Name Qty. 3001-508-800 Bed Exit Keypad Cable 2030-000-154 Bed Exit Label 3002-508-010 Bed Exit Lid Label 3001-508-030 Bed Exit Module 3002-507-030 Scale Module 2030-000-902 Scale Module Label 3002-507-011 Scale Lid Label Return To Table of Contents www.stryker.com 2030-809-002 REV D...
3002-507-030 Scale Module Assembly 2030-000-902 Scale Module Label 3002-507-011 Scale Lid Label 2030-000-156 Chaperone II Module Label 3002-508-012 Chaperone II Label 3002-508-800 Zone Control Keypad Cable 3002-508-030 Zone Bed Exit Module Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Optional Footboard Emergency Drop/Cardiac Chair Module 2025-136-021 Item Part No. Part Name Qty. 3000-508-001 Bed Exit Module Panel 3001-400-953 Switch Cap 2025-136-900 CPR Drop/Card. Ch. Keypad 0023-087-000 Hi-Low Tapping Screw Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Optional Footboard Bed Exit Module, Single Zone - 3001-508-030 Item Part No. Part Name Qty. 3000-508-001 Bed Exit Module Panel 3001-400-953 Switch Cap 3001-508-910 Bed Exit Keypad Assembly 0023-087-000 Hi-Low Tapping Screw Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Page 192
Optional Footboard Bed Exit Module, Multi-Zone - 3002-508-030 Item Part No. Part Name Qty. 0023-087-000 Hi-Low Tapping Screw 3000-508-001 End Exit Module Panel 3001-400-953 Switch Cap 3002-508-900 Bed Exit Board Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Footboard Assembly, iBed Awareness Option 3004-500-010 (Reference only) See Detail A DETAIL A Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Page 195
Hinge Plate 3002-500-025 Lid Label 3004-500-008 LBS Footboard Indicator Light, Ass’y. 3004-553-011 LBS Footboard PCB Assembly 3003-500-801 Footboard CAN Cable 3003-500-804 Lens Footboard Cable 3003-508-007 Scale Label 3003-508-008 Bed Status Label Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Part Name Qty. 2035-500-008 Bumper Strip 2035-500-007 “C” Bumper 3001-400-522 Button Cap 2032-508-004 LBS Footboard Lens Label 2032-508-003 Single Zone Footboard Label 0072-002-071 Cyanoacrylate Adhesive (grams) 0.30 3003-508-006 Bed Exit Label Return To Table of Contents 2030-809-002 REV D www.stryker.com...
2035-500-008 Bumper Strip 2035-500-007 “C” Bumper 3001-400-953 Switch Cap 2032-508-004 LBS Footboard Lens Label 2032-508-002 Multi Zone Footboard Label 0072-002-071 Cyanoacrylate Adhesive (grams) 0.30 3003-508-009 Bed Exit With Zone Control Label Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Pendants Assembly 3001-315-012 Combination Pendant 3001-315-016 Combination Pendant Motion/Communication Communication Only 3001-315-014 Combination Pendant 3001-315-018 Combination Pendant Motion Only Motion/NurseCall Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Optional Head End 2-Stage I.V. Assembly - 2035-112-000 Item Part No. Part Name Qty. 1015-024-035 Retaining Pin 0021-088-000 Set Screw 2035-112-001 I.V. Receptacle, Head, Left 2035-112-010 I.V. Pole Assembly, Left 3000-311-016 I.V. Rest 2035-112-110 Specification Label Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Optional I.V. Pole Transducer Mount Assembly - 2035-018-010 Item Part No. Part Name Qty. 0024-063-000 T-Knob 0024-064-000 Thumb Screw 2035-018-011 Transducer Mount Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Optional Pump Rack Assembly - 2040-111-000 Item Part No. Part Name Qty. 0058-087-000 End Cap 2030-140-002 Pump Rack Label 2040-111-005 Pump Rack Tube Return To Table of Contents www.stryker.com 2030-809-002 REV D...
Optional Siderail Pad Set - 3003-336-020 Item Part No. Part Name Qty. 3003-336-011 Siderail Padded Cover, Head End 3003-336-013 Siderail Padded Cover, Foot End Return To Table of Contents 2030-809-002 REV D www.stryker.com...
Guidance and Manufacturer’s declaration - Electromagnetic Immunity The Epic II® Critical Care Bed is suitable for use in the electromagnetic environment specified below. The customer or the user of the Epic II® Critical Care Bed should assure that it is used in such an environment. Electromagnetic...
Page 221
EMC Information EPIC II® CRITICAL CARE BED (CONTINUED) Recommended separation distances between portable and mobile RF communications equipment and the S3 MedSurg Bed. g Bed is intended for use in an electromagnetic environment in which radiated Epic II® Critical Care RF disturbances are controlled.
Page 222
EPIC II® CRITICAL CARE BED (CONTINUED) The Epic II® Critical Care Bed is suited for use in the electromagnetic environment specified below. The customer or the user of the Epic II® Critical Care Bed should assure that it is used in such an environment. Compliance...
Page 223
The Epic II® Critical Care Bed is intended for use in an electromagnetic environment specified below. The customer or the user of the Epic II® Critical Care Bed should assure that it is used in such an environment. Emissions Test...
Stryker’s obligation under this warranty is expressly limited to supplying replacement parts and labor for, or replacing, at its option, any product which is, in the sole discretion of Stryker, found to be defective. If requested by Stryker, products or parts for which a warranty claim is made shall be returned prepaid to the factory. Any improper use or any alteration or repair by others in such manner as in Stryker’s judgment affects the product materially and adversely...
Claim will be limited in amount to the actual replacement cost. In the event that this information is not received by Stryker within the fifteen (15) day period following the delivery of the merchandise, or the damage was not noted on the delivery receipt at the time of receipt, the customer will be responsible for payment of the original invoice in full.
Page 228
UNITED STATES Stryker Medical 3800 E. Centre Ave., Portage, Michigan USA 49002 Stryker Medical 3800 E. Centre Ave. Portage, Michigan 49002 2016/09 2030-809-002 REV D www.stryker.com...