Guide values for mains connection

The power cable must be dimensioned by a qualified person in accordance with national and local regulations. The
mains socket to which the machine is connected must be dimensioned for the same amperage as the machine's
electrical socket and extension cable, e.g. a 63 A electrical socket must be preceded by a 63 A fuse.
Motor - 18,5 kW (DXR250, DXR270)
Nominal
Min. voltage
voltage from
at machine
power source
V
400
400
400
460
460
460
Motor - 22 kW (DXR300, DXR310)
Nominal
Min. voltage
voltage from
at machine
power source
V
V
400
380
400
380
400
380
460
440
460
440
460
440
*The cable lenght is calculated with respect to a voltage drop of 20 V during operation. Type of power source and wiring
from power source to power outlet affects possible cable length.

The hydraulic system pressure

Type of pressure
Pump pressure
The pressure in the pipes between pump and main
stop valve. The pressure varies between standby
pressure and max. pressure depending on which
hydraulic functions are being used.
Pressure cutter (DXR310)
Functions equipped with pressure cut-off can never
be run at a higher pressure than that indicated. The
following functions are equipped with pressure cut-
off for the respective pressure level.
Standby pressure*
* The pressure that the pump delivers when no function is activated and the circulation valve is shut.
** Arm pressure is limited to 2176/150 PSI/bar when operating the steel shears.
72 – English

TECHNICAL DATA

Cable area
2
V
AWG/mm
380
9/6
380
7/10
380
5/16
440
9/6
440
7/10
440
5/16
Cable area
2
AWG/mm
9/6
7/10
5/16
9/6
7/10
5/16
Starting
current
A
80
80
50 Hz
80
80
80
60 Hz
80
Starting
current
A
90
90
50 Hz
90
90
90
60 Hz
90
Tool, max
Rotating function
Outrigger/dozer blade down/up
Arm functions
Telescopic arm Out/in
External hand tool
Setting
Motor
thermal
output
overload
relay
kW
A
18,5
35
18,5
35
18,5
35
21,3
34
21,3
34
21,3
34
Setting
Motor
thermal
output
overload
relay
kW
A
22,0
41
22,0
41
22,0
41
24,5
39
24,5
39
24,5
39
Pressure, PSI/bar
3626/250
2466/170
3626/2901 / 250/200
2901 (2176**) / 200 (150**)
2611/2901 / 180/200
725-3626 / 50-250
290+/-14,5 / 20+/-1
Max. cable
length*
ft/m
673/205
1132/345
1821/555
689/210
1165/355
1870/570
Max. cable
length*
ft/m
581/177
971/296
1552/473
614/187
1020/311
1634/498