Joystick calibration
SERVICE
When entering the menu, please make sure the joysticks are in neutral position.
•
To calibrate machine speed and tool speed potentiometer, turn them to maximum and minimum positions.
•
To calibrate joysticks, move left and right joysticks into maximum position in all 4 directions.
When a joystick have been calibrated it will be indicated on the screen. It is possible to calibrate an individual axis, but
to get the best behavior, calibrate all joystick functions and potentiometers before pressing save.
Mating Bluetooth®-radio modules
Used for remating the remote control with another machine. During mating, the machine and the remote control must be
connected to each other by a cable.
Units
Setting of units for pressure and temperature that should be shown in the display. Press the selection key to confirm the
choice.
Terminal diagnostics
Test menu for the functions in the terminal (remote control). Joysticks, potentionmeters and pushbutton can be tested.
SYSTEM INFORMATION
SERVICE
This shows the version of the software in the terminal and the two control modules.
SETTINGS
TUNING
JOYSTICK
JOYSTICK CALIBRATION
Up/Down
Left/Right
Thumb Switch
Calibrate Joysticks
Move Joysticks to end positions
Left control
Right control
Up/Down
Left/Right
Thumb Switch
Machine speed
Save
Tool speed