Troubleshooting - Daikin FUA71AVEB Operation Manual

Split system air conditioners
Hide thumbs Also See for FUA71AVEB:
Table of Contents

Advertisement

• A continuous flow "Shah" sound is heard
when the air conditioner is in the
COOLING OPERATION or at a stop.
The noise is heard when the drain pump is in
operation.
Liquid removed from the indoor air during the
COOLING OPERATION is discharged.
• A "Pishi-pishi" squeaking sound is heard
when the air conditioner is in operation or
after the stop of operation.
Expansion and contraction of resin parts
caused by temperature change makes this
noise.
VIII. DUST FROM THE INDOOR UNITS
• Dust may blow out from the unit after
starting operation from long resting time.
Dust absorbed by the unit blows out.
IX. THE INDOOR UNITS GIVE OFF ODORS
• During operation
The unit absorbs the smell of rooms,
furniture, cigarettes, etc., and then emits
them.
If odor is a concern, set the fan speed to no
airflow when the indoor temperature reaches
the set temperature.
For details, contact your local dealer.
X. THE AIR CONDITIONER DOES NOT COOL
EFFECTIVELY
• The air conditioner is operating in
PROGRAM DRY OPERATION.
This is because program dry mode operates
so that the indoor temperature decreases as
little as possible.
Lower the indoor temperature using the
COOLING OPERATION, and then use the
PROGRAM DRY OPERATION.
(Refer to "CHARACTERISTICS OF THE
PROGRAM DRY OPERATION" on page 7.)
• Read through characteristics of the
COOLING OPERATION, characteristics of
the HEATING OPERATION, and
characteristics of the PROGRAM DRY
OPERATION on page 7.

10. TROUBLESHOOTING

Please check before requesting a service.
1. If the air conditioner does not operate at all.
• Check if fuse has blown.
Turn off the power supply.
English
• Check if the power circuit breaker is blown.
If the tab of power circuit breaker is in the OFF
position, turn the power on with the power
circuit breaker switch.
If the tab of power circuit breaker is in the trip
position, do not turn the power on with the
power circuit breaker switch.
Contact your local dealer.
1
1
Power circuit breaker (earth leakage breaker)
2
Tab
3
Trip position
• Check if there is a power failure.
Wait until power is restored. If power failure
occurs during operation, the air conditioner
automatically restarts immediately after the
power supply recovers.
2. If the air conditioner stops after operating the
air conditioner.
• Check if the air inlet or outlet of outdoor or
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-
ventilated.
The horizontal blades at the air outlet are
closed while the indoor stops.
• Check if the air filter is clogged.
Ask a qualified service person to clean the air
filters.
A decrease in the airflow volume of the air
conditioner will result and the performance of
the air conditioner will be degraded and power
consumption will increase if the air filter is
clogged with dust or dirt.
In addition, this may cause dew condensation
at the air outlet.
(Refer to "MAINTENANCE (FOR SERVICE
PERSONNEL)" on page 8.)
3. The air conditioner operates but it does not
sufficiently cool or heat.
• Check if the air inlet or outlet of outdoor or
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-
ventilated.
The horizontal blades at the air outlet are
closed while the indoor unit stops.
Obstacles decrease the fan speed, and cause
performance decrease and breakage when
discharged air is suctioned.
They cause a waste of electricity, and that
may stop the devices.
ON
2
3
OFF
14

Hide quick links: