TROUBLESHOOTING

A) Atomiser disc spins but does not spray or sprays irregularly. Check:
- The feed nozzle. If the feed nozzle is blocked remove and soak in soapy water.
blow through the nozzle with your mouth. Check that the feed nozzle
Never
gives a flow rate within the operating range.
- The atomiser is clean and undamaged. Clean or replace.
- The flow valve for blockage. Rinse through with soapy water.
B) Atomiser disc fails to spin or spins unevenly. Check:
- Charging was done correctly.
Switch
3
should be in ON position when charging, 3 pole connector is connected
properly.
- The condition of the batteries. Replace if necessary.
- That electrical terminals and contact points are clean and that electrical wires are
not broken or corroded.
- If the atomiser disc is rubbing on the motor base plate or the motor shaft is bent.
Replace the disc or motor if necessary.
- The motor for corrosion or obvious signs of wear. Replace if necessary.
N.B. Battery condition can be checked with a torch (or a torch lightbulb and electrical
wire).