  • Page 1 Operator’s Manual Publication Part No: 9654 Revision: 4...
  • Page 3 This publication covers the following products: InjectorDos Pro This document is prepared for Micron Sprayers Ltd. their agents and clients. The document should be taken in its entirety. No responsibility can be accepted, nor can consent be assumed for the part reproduction, editing, extract or quotation taken out of context of this document.
  • Page 4 Readers should pay particular attention to the ‘Important Information’ section of this document. Please contact Micron Group or their agents if you require any assistance. While reading this document please be aware of the following conventions: Bold text has been used to highlight information of particular interest.
  • Page 5 This document has been written to provide the information to correctly install and use the equipment safely. Various symbols are used on the equipment and in this document to provide guidance to the operator; please take time to become familiar with these symbols. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 6 Face Shield – Gloves – Protective Boots – must be worn must be worn must be worn Harmful – Toxic – Danger to the substance is environment– risk of contact risk of harmful with toxic contamination substances Micron Sprayers Ltd. InjectorDos Pro...
  • Page 7 The equipment should not be used to with the following materials. ▪ Any form of petrochemical fuel or oil. ▪ Acids. ▪ Concentrate solvents. For lubricating fluids refer to the maintenance section of this document. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 8: Table Of Contents

    WORKING WITH PESTICIDES 2.1.1 OPERATOR PROTECTION 2.1.2 PRODUCT LABELS 2.1.3 STORAGE OF PESTICIDES PROTECTION OF THE ENVIRONMENT PREPARING FOR USE APPLICATION METHOD CLEANING DISPOSAL OF RINSATE MAINTENANCE TROUBLESHOOTING DISPOSAL PARTS LIST APPENDIX A - CONVERSION FACTORS Micron Sprayers Ltd. InjectorDos Pro...
  • Page 9: Introduction

    The InjectorDos Pro comes with a one litre Backpack to replenish the applicator via a length of hose. Liquid supply can be shut off using an in- line tap. System Features Injector unit Backpack 1 Litre Spears (2 sizes) Hose connection cap In-line tap Storage cap Micron Sprayers Ltd. InjectorDos Pro...
  • Page 10: Technical Specification

    Metered-dose injection applicator for invasive weed control Model: InjectorDos Pro Manufacturer: Micron Sprayers Ltd. Weights and Measures Net weight: 475 g Dose range: 0.1– 2.0 ml Backpack Capacity: 1 Litre Environmental Conditions Minimum working temperature: +5°C Micron Sprayers Ltd. InjectorDos Pro...
  • Page 11: Safety

    When connecting or disconnecting hoses to the equipment; always grasp the connector directly, do not hold by or pull on the hose as this may cause damage. Always wear personal protective equipment when instructed. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 12: Working With Pesticides

    Operators MUST adhere to the required use of personal protective equipment (PPE). When handling concentrates operators should wear gloves, coveralls, boots and a face shield to protect eyes and skin from accidental splashes. Some products may also require the use of a respirator mask. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 13: Product Labels

    Tank washings and rinsate should always be sprayed out onto either the treated crop (taking care not to exceed maximum dose rates) or onto a designated area. Always avoid run-off into ditches or waterways. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 14: Preparing For Use

    360gl glyphosate e.g., Roundup ▪ Screw the supplied hose connector cap onto the backpack. ▪ Push on the free end of hose and secure it in place with the supplied thumbscrew hose clip. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 15 ▪ Ensure that the spear tip is fitted into the recess and not against the back face of the knurled end. If the spear tip is fitted incorrectly, it may leak or break when used. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 16: Application Method

    2nd and 3rd node, generally using a single dose of 2ml of undiluted glyphosate. NOTE. Never force the Injector syringe if resistance is experienced. Withdraw the needle and check that it is not blocked. Clean if necessary. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 17: Cleaning

    It is the responsibility of the user to ensure all possible measures are taken to protect the environment. It is the responsibility of the user to be familiar with, and adhere to, all relevant national and local restrictions, prohibitions and regulations. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 18: Maintenance

    Clean the injection applicator regularly with warm water and detergent. ▪ Periodically remove the syringe barrel and lubricate the ‘O’ ring with a light oil. A service kit is available from Micron Sprayer Ltd. eedle ut ush Rod eal Ring eedle Mount...
  • Page 19: Disposal

    To dispose of the equipment, reduce the equipment to its component parts. Thoroughly clean all component parts inside and out. Dispose of the component parts by material and type in accordance with all national and local restrictions, prohibitions and regulations. Micron Sprayers Ltd. InjectorDos Pro...
  • Page 20: Parts List

    PARTS LIST Injectordos Pro, Standard Components Micron Sprayers Ltd. InjectorDos Pro...
  • Page 21 CAP, 38 mm, C/W WAD 7666 BACKPACK STRAP (FOR 7665) 8032 SPEAR, STANDARD (INJECTORDOS) 8033 SPEAR, FINE (INJECTORDOS) 9592 CONTAINER, INJECTORDOS SPEARS FUNNEL, 100mm DIAMETER, 5843 POLYPROPYLENE 9624 GLOVES, UNLINED, SIZE 9 9610 CASE, INJECTORDOS PRO KIT Micron Sprayers Ltd. InjectorDos Pro...
  • Page 22: Appendix A - Conversion Factors

    35.3 ounces 1 kilogram 28.35 grams 1 ounce 0.068 atmosphere 0.067 bar 1 pound/sq inch 14.70 pounds/sq in 1.01 bar 1 atmosphere 14.50 pounds/sq in 0.98 atmosphere 1 bar 0.01 bar 0.145 pounds/sq in 1 kilopascal Micron Sprayers Ltd. InjectorDos Pro...
  • Page 23 TABLE OF CONTENTS ........8 MICRON GROUP ..........4 TECHNICAL SPECIFICATION ....... 10 MICRON GROUP ADDRESS ......28 TROUBLESHOOTING ........18 OPERATING INSTRUCTIONS .......14 UNCOUPLING ..........18 OPERATOR PROTECTION ......12 WARNINGS ............ 11 PARTS LIST ............20 Micron Sprayers Ltd. InjectorDos Pro...
  • Page 24 Notes Micron Sprayers Ltd. InjectorDos Pro...
  • Page 25 Notes Micron Sprayers Ltd. InjectorDos Pro...
  • Page 26 Notes Micron Sprayers Ltd. InjectorDos Pro...
  • Page 28 Copyright © Micron Sprayers Ltd. 2023 General Enquiries: Micron Sprayers Ltd. Goizper Group Antigua, 4 Porthouse Industrial Estate, 20577 Antzuola Bromyard, Herefordshire, Gipuzkoa - Spain HR7 4HS, U.K. T + 34 943 786 000 T +44 (0)1885 482397 E goizper@goizper.com F +44 (0)1885 483043 E enquiries@micron.co.uk...