Hazardous Area Approvals
XNX-UT**-*****
UL Classified and CSA Listed (see notes below)
Class I, Div. 1 Groups B, C & D Class I, Zone 1 Groups IIB + H2
UL Classified
Class II, Div. 1 Groups F & G, Class II, Zone 20 & 21
FM Approvals Listed
AEx d IIB + H2 T6 -40 ºC ≤Tamb ≤65 ºC
AEx d [ia IIC] IIB + H2 T6 -40 ºC ≤Tamb ≤65 ºC (XNX UT*E-***** & XNX-UT*-*H****)
XNX-AM**-*****
UL/Demko 09 ATEX 0809943X / IEC Ex UL 09.0010X
II 2 G Ex d IIB + H2 T6 (Tamb -40 ºC to +65 ºC) IP 66
II 2 D Ex tb IIIC T85 C Db
XNX-AM*E-***** & XNX-AM*-*H****
II 2 (1)G Ex d [ia IIC Ga] IIB + H2 T6 (Tamb -40 ºC to +65 ºC) IP 66
II 2 (1)D Ex tb [ia IIIC Da] IIIC T85 Db
XNX-BT**-*****
UL Classified
Class I, Div. 1 Groups B, C & D Class I, Zone 1 Groups IIB + H2
Class II, Div. 1 Groups F & G, Class II, Zone 20 & 21
INMETRO TUV 12.1018X
Ex d IIB + H2 T4 Gb IP 66 ≤ -40 ºC ta ≤+65 ºC
Ex d [ia IIC Ga] IIB + H2 T4 Gb IP 66 ≤-40 ºC ta ≤+65 ºC (XNX BT*E-***** & XNX-BT*-*H****)
FM Approvals Listed
AEx d IIB + H2 T6 -40 ºC ≤Tamb ≤65 ºC
AEx d [ia IIC] IIB + H2 T6 -40 º≤ Tamb ≤65 ºC (XNX BT*E-***** & XNX-BT*-*H****)
NOTES:
1. The temperature class (T6) is limited to T4 when the MPD sensor is attached locally to the transmitter.
2. XNX EC cartridges and Remote Mount Kit have been evaluated by Underwriters Laboratories (UL) to
Canadian National Standards.
3. CSA Listing is only to Class I, Division 1 does not include Class II, Div.1 approval
4. Peer to peer and multi-drop network (daisy chained) HART, Modbus®, and FoundationTM Fieldbus
configurations have not been evaluated by CSA to the requirements of CSA 22:2 No. 152 for
Combustible Gas Detection and may be used only for diagnostics and data collection.
Performance Approvals
See section 6.3 of the XNX Technical Manual, Certifications by Part Number , for other approvals.

Communication Options

Relays
Modbus
®
Fountation
Fieldbus
XNX Universal Transmitter Quick Start Guide
Type: 3 form "C" SPCO contacts for alarm and fault indication.
Rating: 250 VAC, 5A/24 VDC, 5A (2 Alarm, 1 Fault)
A remote reset is provided to silence alarms. Foundation fieldbus,
Modbus, and relay options ae mutually exclusive.
Modbus/RTU over RS-485 physical layer.
Interface isolated; includes switchable 120 Ohm termination resistor.
Baud rates: 1200 to 38,400; 19,200 default. Foundation Fieldbus, Modbus, and
relay options are mutually exclusive.
H1 Physical Layer.
31.25 kbit/s Manchester encoded signal.
AMIS-49200 Fieldbus MAU (media access unit).
SPC4-2 Fieldbus Controller.
Do not use Fieldbus communication in hazardous areas.
Foundation Fieldbus, relay, and Modbus options are mutually exclusive.