2.2. ASSEmBly

2.2.1. VIDEO OuTPuT

The OTS incorporates a sealed Connector used for video transmis-
sion and to connect external power sources. Video Cable attaches
the scope to the video facilities for video recording or video trans-
mission to the external display.
Connect the monocular to an external video display/recorder as
follows:
1. Remove the protective cap from the connector socket.
2. Attach the video cable to the OTS output connector socket.
3. Attach the RCA plug of the video cable to a compatible jack
on an external video display/recorder, or extension cable.

2.2.2. hEAD mOuNT

The operator can mount the monocular onto the head bracket using
any of two Mounting Rail located on the opposite sides of the body,
to be able to see through the eyepiece with his/her right or left eye
correspondingly.
To mount the OTS-17 to a headmount, perform the following:
1. Loosen the screw (1). Push the button (2) and insert the rail
of the OTS-17 into the socket (3) of the headset.
2. Place the headmount with OTS-17 onto a head.
3. Loosen the screw (1) and move the unit along the rail for eye
relief adjustment.
2-4