Electrolux EYL85016WM User Manual page 14

Table of Contents

Advertisement

14
www.electrolux.com
5. INSTALLATION
NOTE:
through to remove debris and swarf that
could otherwise damage the unit.
A proper sealant should always be used
to seal around the incoming pipework to
prevent water entering the wall.
If entry is from the back, the nut of the
the surface of the wall. This area MUST
be left clear when plastering and tiling
around the pipework in order to make the
nut accessible for future adjustments(Fig. 5).
Fig. 5
To check the water supply leak
Turn on the mains water supply and check
for leaks in the pipework connection to the
shower.
NOTE:
through the unit.
21mm
5.3
Electrical wiring connection
To select the wiring terminal position
This Electrolux shower heater has 2 wiring
terminals and 2 earthing terminals shown
as Fig. 6. You can choose the proper
terminals when connecting the wiring.
Fig. 6
Warning
only one of the terminal blocks is to used
for the supply cable connection, the other
terminal block is not to be used.
To do the wiring connection
Route the cable into the shower unit for
connection to the terminal block as follows:
Earth:
cable to terminal marked
Neutral:
cable to terminal marked
Live:
cable to terminal marked
Important!
When connecting the cable fully tighten the
terminal block screws and make sure that
no cable insulation is trapped under the
screws. Loose connections can result in
cable overheating.
Fixing the front cover
5.4
1. Before fixing the front cover to the shower,
tighten the 3 screws to fix the shower on the
wall firmly.
2. Adjust the spline spindle and the control
knob to the correct position before replacing
the cover Fig. 7, 8 show the correct pline
spindle and the control knob position.
Wiring terminal.
Earthing terminal.
N
L

Hide quick links: