Fujitsu SPARC Enterprise M3000 Product Notes page 78

Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

Oracle Solaris OS Issues Fixed in Oracle Solaris 10 8/07 (Continued)
TABLE 3-11
M4000
CR ID
M3000
M5000
6496337
O
6498283
O
64
SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1112 • May 2012
M8000
M9000 Description
O
The "cpumem-diagnosis" module may
fail to load after uncorrectable error(UE)
panic.
Systems will function correctly but
events normally automatically
diagnosed by FMA using this module
will require manual diagnosis.
Example:
SUNW-MSG-ID: FMD-8000-2K,
TYPE: Defect, VER: 1,
SEVERITY: Minor
EVENT-TIME: Thu Feb 15
15:46:57 JST 2007
PLATFORM: SUNW,SPARC-
Enterprise, CSN: BE80601007,
HOSTNAME: col2-ff-em7-d0
O
Using the DR deleteboard(8)
command while psradm operations are
running on a domain might cause a
system panic.
Workaround
For Oracle Solaris 10 11/06, this has
been fixed in patch 125369-05.
[Workaround]
If problem occurred, implement the
following
workaround:
1. Remove the following file.
# rm
/var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
2. Restart fmd service.
# svcadm restart fmd
To avoid this problem in advance,
add "rm -f
/var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis" in
/lib/svc/method/svc-dumpadm file
as below.
#
# We haven't run savecore on
a dump device yet
#
savedev=none
rm -f
/var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
#
For Oracle Solaris 10 11/06, this has
been fixed in patch 120011-07.
No workaround is available.

Advertisement

Table of Contents
loading

Table of Contents