ATSG AXOD Update Handbook page 114

Table of Contents

Advertisement

CONNECTING THE DVOM TO CHECK AMPS TO THE TRANSAXLE
To Pin 38
WHITE/YELLOW
At Computer
Cut the White/Yellow wire from Pin No. 38 at the computer and connect the DVOM
leads, as shown above, to perform this test. This is known as "connecting in series".
EPC AMPS
*
With a normally functioning EPC circuit, you will see about 150 PSI on the
pressure gauge while in Park, on "the initial start up", which is part of the
computer strategy, "and is normal".
Technical Service Information
FLUKE 88
FLUKE 88
AUTO
V
RPM
V
OFF
A
10A Max
FUSED
1.0
.90
EPC PSI
20
30
*
P psi
75
----
R psi
90
145
----
N psi
75
OD psi
75
100
D psi
75
100
L psi
80
100
Figure 99
AUTOMATIC TRANSMISSION SERVICE GROUP
DC
00.75
A
mV
mA
A
mA
A
V
mA
COM
RPM
.75 .70 .60 .50 .35
40
50
60
70
80
----
----
----
----
----
175
200
225
275
310
----
----
----
----
----
125
145
165
180
210
125
145
165
180
210
125
155
175
190
220
114
WHITE/YELLOW
To Transaxle
Case Connector
Copyright © 2002 ATSG

Advertisement

Table of Contents
loading

Related Products for ATSG AXOD

This manual is also suitable for:

AxodeAx4s

Table of Contents