Continuity Test - Fluke 1587 FC Calibration Manual

Insulation multimeters
Hide thumbs Also See for 1587 FC:
Table of Contents

Advertisement

Continuity Test

Continuity Indication ........................................... Continuous audible tone for test resistance below 25 Ω and off above
Open Circuit Voltage ........................................... <8.0 V
Short Circuit Current ........................................... 1.0 mA typical
Overload Protection ............................................ 1000 V rms
Response Time ................................................... >1 m sec
Frequency Measurement (all 1587 models)
Range
99.99 Hz
999.9 Hz
9.999 kHz
99.99kHz
Frequency Counter Sensitivity (all 1587 models)
Input Range
600.0 mV ac
6.0 V
60.0 V
600.0 V
1000.0 V
[1]
Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy.
[2]
Usable to 100 kHz with full scale input.
Capacitance (all 1587 models)
Range
1000 nF
10.00 μF
100.0 μF
9999 μF
Temperature Measurement (all 1587 models)
Range
-40 ° C to 537 ° C
-40 ° F to 998 ° F
[1]
Specifications apply following 90 minutes settling time after a change in the ambient temperature of the instrument.
Insulation Test
Measurement Range
Model 1587, 1587 FC ................................. 0.01 MΩ to 2 GΩ
Model 1577 ................................................. 0.1 MΩ to 600 MΩ
Model 1587T ............................................... 0.01 MΩ to 100 MΩ
Test Voltages
Model 1587, 1587 FC ................................. 50, 100, 250, 500, 1000 V
Model 1577 ................................................. 500, 1000 V
Model 1587T ............................................... 50, 100 V
Test Voltage Accuracy ........................................ +20 %, -0 %
Short-Circuit Test Current ................................... 1 mA nominal
Auto Discharge ................................................... Discharge time <0.5 second for C = 1 μF or less
Live Circuit Detection .......................................... Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum Capacitive Load ................................. Operable with up to 1 μF load
100 Ω. Maximum Reading; 1000 Ω
Resolution
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
V ac Sensitivity (RMS Sine Wave)
5 Hz to 20 kHz
20 kHz to 100 kHz
100.0 mV
1.0 V
10.0 V
100.0 V
300.0 V
Resolution
1 nF
0.01 μF
0.1 μF
1 μF
Resolution
0.1 °C
0.1 °F
Specification ±(% of Rdg + Counts)
±(0.1 % + 1)
±(0.1 % + 1)
±(0.1 % + 1)
±(0.1 % + 1)
[1]
DC Trigger Levels
150.0 mV
1.5 V
-400.0 mV and 2.5 V
36.0 V
-
12.0 V and 40.0 V
-
12.0 V and 40.0 V
Specification ±(% of Rdg + Counts)
±(1.2 % + 2)
±(1.2 % ±90)
[1]
±(% of Rdg + Counts)
Specification
±(1 % + 10)
±(1 % + 18)
Insulation Multimeters
Electrical Specifications
[1]
[2]
to 20 kHz
na
1.2 V and 4.0 V
9