Increase Quality Through Interaction with the Field
13. Trim back the jacket (outer covering) for a convenient lead length on both harnesses so you
can strip (3/8") the wires.
14. For stability cable tie both harnesses together before connecting leads.
15. Connect the leads together: white/white, blue/blue, red/red & black/black.
16. Bend the harnesses to fit under the ionizer generator.
17. Place the ionizer generator over the harnesses and fasten with one screw.
18. Place the motor mounts on the motor.
19. Fit the motor bracket over the motor and fasten with four screws.