Download Print this page

Oreck 8143 Service Manual page 15

Advertisement

Increase Quality Through Interaction with the Field
5. Touch the other lead to the back of the power switch where the black, (brown or blue) and
red.
6. If you get a ∞ reading in any position then the motor is bad.
7. Check the Interlock/Safety switch by removing the two leads (Fig F).
8. Touch the Multimeter leads to the switch terminals and press in the switch button with a small
blunt object (Fig G). If the meter goes to 0 then the switch is good.
F
Remove and Replace the Motor
1. Turn the unit over and remove nine (9) screws.
2. Turn the unit back over and carefully remove the top housing.
3. You may need to reach in and pull down the fan assembly if it's caught in the top housing
(Fig H).
H
Increase Quality Through Interaction with the Field
G
15

Advertisement

loading