Gently clean the two metal contacts of the cell interconnect board with a plastic safe
contact cleaner/lubricant and soft cloth.
Use Zoom Spout or equivalent to lubricate the fan bearing.
11. Finishing Up
Cell High Voltage function can be verified. Method can be performed with or without
the top cover installed. Safety First-If performed without the top cover installed
remove the fan.
Neon Bulb Circuit Tester: Caution-the condition is a static charge. Manage the tester
lead so you don't have to hold the tester. Touch the front cell contact with one leg of
the inexpensive circuit tester shown in Figure A1. Leave the other leg dangling. Turn
the unit on and enable the safety switch as shown in A2. If the neon bulb of the tester
doesn't light up then the HV Power Supply is defective.
A1
Negative HV Power Supply Test-Ionizer Generator function can be verified. Safety
First – Remove top cover and fan.
Caution-the condition is a static charge. Manage the lead so you don't have to hold
the tester.
Rest the end of the test lead on the ionizer needle.
Turn the unit ON and insure the IONIZER switch is in the IONIZER position.
The bulb will glow if the ion generator is working.
Increase Quality Through Interaction with the Field
Fix tester lead to this
contact point.