Pumped Liquids; Caution; Installation; Electrical Connection - Grundfos Sololift2 CWC-3 Installation And Operating Instructions Manual

Small, compact automatic lifting station suitable for pumping domestic wastewater and sewage off places in private dwellings where wastewater cannot be led directly to the sewer by means of a natural downward slope
Table of Contents

Advertisement

4. Pumped liquids

Domestic wastewater and sewage containing toilet
paper and faeces.
Ordinary liquids for cleaning of the appliances
connected. pH value: 4-10.
The product must not pump harsh
chemicals or solvents. See the quick
guide.

Caution

The product is designed for flush volumes
of 4, 6 and 9 litres. A 4-litre flush is
permissible only if the amount of solids in
the pumped liquid is small.

5. Installation

Do not pull or lift the product by the power
Caution
supply cable.
The product must be accessible for
maintenance and repair.
If the product is installed behind the wall, a
service hatch of sufficient size is
necessary.
The product must be placed in a frost-free
room to prevent the pumped liquid from
freezing.
Make sure that all external pipework is
Note
adequately insulated.
The discharge pipe must be made of rigid
material, such as copper, or of rigid PVC
with solvent-welded joints.
To prevent the transmission of vibrations
to buildings, make sure that the pipework
is thoroughly fixed and that fittings cannot
move and are not in contact with building
parts.
An alarm device for acoustic alarm in case of
malfunction or high level in the tank is available as
an accessory (noise level 75 dB(A)). Product
number: 97772315.
Alarm device
Fig. 1

6. Electrical connection

Make sure that the product is suitable for the supply
voltage and frequency available at the installation
site.
The electrical connection must be carried out in
accordance with local regulations.
Warning
The product must be earthed. The
protective earth of the socket outlet must
be connected to the protective earth of the
pump. The plug must therefore have the
same PE connection system as that of the
socket outlet. If not, use a suitable
adapter.
The installation must include an earth
leakage circuit breaker for protection
against earth fault currents. This will
ensure protection when using a Schuko
plug or another plug with earth pin.
Warning
The product must be connected to a mains
switch with a minimum contact gap of 3
mm in all poles.
The thermal switch cuts out the motor in case of
overtemperature and cuts it in again automatically
after cooling.