Installation Instructions E-Series Dental Cabinetry Model: E-120 & Owners Manual Consumer: Please retain these instructions for future use. 1631 Dr. Martin Luther King Drive St. Louis, MO 63106 (314) 231-7383 (888) 833-3682 Fax (314) 621-2296 www.belmontequip.com Version: 03282013...
Page 2
General Cabinet Handling Information Models: E-120 DO NOT Lift cabinet by the Ultrasonic pull-out when moving. See Figure A. Note: Remove any drawers to help reduce weight when moving cabinetry. Lift by gripping front & rear vertical edges of cabinet body.
Page 3
Detail Drawings Model: E-120 NOTE: TT1684-24 requires 6” of clearance for door rotation.
Page 5
Assembly Instructions Model: E-120 NOTE: Assembly instructions are based on the standard E-120 Sterilization Center. Each site installation may contain a different combination of cabinetry but in general all installation guidelines are the same. Step 1 Confirm that the appropriate plumbing supply/drain and electrical rough-ins are in place.
Page 6
Step 3 (Continued) Assembly Instructions Cabinet hangers have a 5/8” vertical adjustment Model: E-120 and 9/16” depth adjustment (see Figure 2C). Figure 2C Step 4 Hang remaining Wall Cabinets (K & L) (see Figure 3A). Secure Wall Cabinets together by inserting (4) Connectors through the (4) holes in each Wall Cabinet end panel and tightening with screw drivers (see Figure 3B).
Page 7
Assembly Instructions Model: E-120 Step 6 Move Tall Tower Storage Cabinet (I) into position flush against the wall and against the last Sterilization Cabinet (H) (see Figure 5A). Plug the interior lamps into a floor outlet controlled by customer supplied light switch through the access hole at the bottom rear corner of theTall Tower Storage Cabinet (I).
Page 8
Assembly Instructions Model: E-120 Step 7 Mount the Leg Leveler (D3) to the Leg Leveler Base (D4) by inserting into the Leveler Base (D4) (see Figure 6A) IMPORTANT When a finished side toe-kick is used, the Leg Leveler Bases (D4) on that side must be removed and rotated 90°...
Page 9
Assembly Instructions Model: E-120 Step 9 Place the cabinets (A thru D) into the proper location (using fillers where needed) (see Figure 8) . Using suppled #6 x 1-1/2” wood screws mount each lower cabinet to cabinet base with (4) wood screws each.
Page 10
Assembly Instructions Model: E-120 Step 11 Place Top (E) onto cabinets with the back edge flush with the wall and the right edge flush with the ST2684-26 Sterilization Cabinet (H) (see Figure 10). Secure the Top (E) to the cabinets by using #8 x 1-1/2”...
Page 11
Assembly Instructions Model: E-120 Step 13 Install Kickplates (G1 & G2) by snapping clips onto legs. (see Figure 12). F R O C A B I I N E T N E T C A B E N D Figure 12...
Page 12
Assembly Instructions Model: E-120 Step 14 Insert Trash Chute (B1) into chute hole in counter top and place Trash Basket (B2) into the slide out basket holder in cabinet (B) (see Figure 16). Install the Soap Dispenser (C6) into the hole in the sink (see Figure 14).
Page 13
Assembly Instructions Model: E-120 Step 17 Insert Towel Dispenser (K3) and Cup Dispenser (K4) into proper openings in Wall Cabinet (K). Insert the Shelf Supports (K5) into the holes in the interior end panels then set the Shelf (K6) onto the Shelf Supports (see Figure 16).
Page 14
Hinge Adjustments Model: E-120 G-Force™ Controlled Hinge Adjustment Closing Device For Standard Doors Rev-04212009...
Surface Cleaning Ortho-Sys. ECO-Sys, D-Series, & E-Series Belmont Recommends: • Countertop Magic® for Laminate and Solid Surface Work Surfaces • Stone Clean and Polish Magic® for Cambria Quartz Work Surfaces • Cabinet and Wood Magic® for Laminate and Melamine Surfaces •...
Need help?
Do you have a question about the E-120 and is the answer not in the manual?
Questions and answers