8. MAINTENANCE
8.6
Train/Tilt Test
This test checks the transducer training and tilting functions for proper operation.
1. Select TRAIN/TILT TEST with [] or [] key from the SYSTEM menu.
2. Press the [MENU] key to start the test.
3. Press the [MENU] key to return the SYSTEM menu again.
4. Press the [PWR] key to quit the operation.
** TRAIN/TILT TEST **
– PHOTO SENSOR CHECK –
TRAIN
0°
180°
– TRAIN CHECK –
0 → 180° ( CW)
180 →
0 → 180° ( CCW)
180 →
– TILT CHECK –
+10 → 90°
90 → 190°
190 → 90°
90 → +10°
EXIT : PRESS MENU KEY
8.7
Test Pattern
This test checks display position and colors.
1. Select TEST PATTERN with [] or [] keys from the SYSTEM menu.
2. Press the [MENU] key to start the test.
Position check
3. Press the [MENU] key to return the SYSTEM menu again.
4. Press the [PWR] key to quit the operation.
8-4
TILT
+10°
OK
OK
180°
OK
OK
190°
OK
PULSES
NG
1428
0
1449
0
0° ( CW)
1427
0
1451
0
0° ( CCW)
PULSES
NG
1206
0
939
0
919
0
1225
0
TEST COUNT = 8
Black
[↓]
Note: The number of pulses
are reference only.
This check the photo sensors
which detect the referense angles
for training and tilting operations.
This checks the transducer
training operation. The four digit
figures used to train the
transducer by 180°.
If training is abnormal, NG count
increases by one.
This checks the transducer tilting
operation. If the number of pulses
used to tilt the transducer is
abnormal, NG count increases by one.
This increases by one when
above test has done.
Red
Green
Blue