FURUNO
SPECIFICATIONS OF COLOR SECTOR SCANNING SONAR
1
GENERAL
1.1
Display system
1.2
Transmitting frequency
1.3
Output power
1.4
Pulse length
1.5
Range
2
PROCESSOR UNIT
2.1
Picture output
2.2
Color hue control
2.3
Display mode
2.4
Sensitivity
2.5
Unit indication
2.6
Horizontal range
2.7
Vertical range
2.8
Display sector width
Horizontal mode
Vertical mode
2.9
Off-center
2.10 TVG
2.11 Clutter
2.12 Elimination interference Correlation with before data
2.13 Audio monitor
CH-37BB
15-inch color monitor (XGA/SXGA) or more recommended
60/113/162 kHz selected
0.8 kW (60 kHz), 1.3 kW (113 kHz), 1.5 kW (162 kHz)
0.2 to 10.6 ms,
varied according to the range in use
Detection range (m)
Range
60 kHz 113 kHz 162 kHz
1
0-50
0-50
2
0-100
0-100
3
1-150
1-150
4
0-200
0-200
5
0-250
0-250
6
0-300
0-300
7
0-400
0-350
8
0-500
0-400
9
0-600
0-500
10
0-800
0-600
11
0-1200
0-800
12
0-1600
0-1000
1024 x 764 pixels, 16 or 8 colors selectable
LOG, linear, square
Vertical (normal, expanded), Slice combination, Sonar combination
Variable continuity
m, ft, fa, HR
12 steps during 30 m to 1600 m
12 steps during 10 m to 1600 m
45°, 90°, 135°, 180°, 225° and 360°
36°, 60°, 96°, 120°, 150° and 180°
4 point at expand mode, according to the train setting
2 point at slice mode, according to the tilt setting
Level (100 dB max.), Range (1000 m max.)
Variable, Hue control
2 W, 8 ohms using external speaker (option)
SP - 1
Train speed (sec)
at 113 kHz
0-50
3.8
0-100
4.3
1-150
4.8
0-200
5.4
0-250
6.0
0-300
6.7
0-350
7.0
0-400
7.6
0-450
8.6
0-500
10.0
0-600
12.0
0-800
14.0